Título: Accuracy of piezoelectric pedometer and accelerometer step counts
Autor: Cruz, Joana
Brooks, Dina
Marques, Alda
Palavras-chave: Actigraphy
Dimensional measurement accuracy
Exercise
Walking
Data: Abr-2017
Editora: Edizioni Minerva Medica
Resumo: This study aimed to: assess step-count accuracy of a piezoeletric pedometer (Yamax PW/EX-510), when worn at different body parts, and a triaxial accelerometer (GT3X+); compare device accuracy; and identify the preferred location(s) to wear a pedometer. METHODS: Sixty-three healthy adults (45.8±20.6 years old) wore 7 pedometers (neck, lateral right and left of the waist, front right and left of the waist, front pockets of the trousers) and 1 accelerometer (over the right hip), while walking 120m at slow, self-preferred/normal and fast paces. Steps were recorded. Participants identified their preferred location(s) to wear the pedometer. Absolute percent error (APE) and Bland and Altman (BA) method were used to assess device accuracy (criterion measure: manual counts) and BA method for device comparisons. RESULTS: Pedometer APE was below 3% at normal and fast paces despite wearing location, but higher at slow pace (4.5–9.1%). Pedometers were more accurate at the front waist and inside the pockets. Accelerometer APE was higher than pedometer APE (P<0.05); nevertheless, limits of agreement between devices were relatively small. Preferred wearing locations were inside the front right (n=25) and left (n=20) pockets of the trousers. CONCLUSION: Yamax PW/EX-510 pedometers may be preferable than GT3X+ accelerometers to count steps, as they provide more accurate results. These pedometers should be worn at the front right or left positions of the waist or inside the front pockets of the trousers.
Peer review: yes
URI: http://hdl.handle.net/10773/22205
DOI: 10.23736/S0022-4707.16.06177-X
ISSN: 0022-4707
Aparece nas coleções: ESSUA - Artigos
Lab3R - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Cruz2016_Accuracy of piezoelectric pedometers and accelerometer.pdf437.43 kBAdobe PDFVer/Abrir


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.