Utilize este identificador para referenciar este registo: http://hdl.handle.net/10773/41299
Título: Frontier Analysis on Optimal Inspection Times for Reinforced Concrete Structures
Autor: Benítez, Pablo
Rocha, Eugénio
Rodrigues, Fernanda
Palavras-chave: Corrosion
Cement
Numerical methods
Probability theory
Data: 2019
Editora: AIP
Resumo: Reinforced concrete is one of the most predominant materials in infrastructures throughout the world, hence management of the structures maintenance is an important subject of study in order to slow down the degradation process and to extend a structure lifespan. This work focus on a numerical model to find the best inspection planning for concrete structures under carbonation- induced corrosion, decomposed in three steps: (a) estimate the probability density function for critical failure time, (b) determine the optimal times for inspections sequences maximising its detectability; (c) multi-objective optimisation via frontier analysis to have a final relative ranking of inspection sequences. In short, this work answer the questions: when the inspections should be done and what are the best inspections for a given efficiency metric, under a set of parameters characterising the degradation process and inspection capabilities. Our formulation extend the models in the literature (e.g. detectability function) and its seems that the multidirectional efficiency analysis algorithm used here is better suited for real situations.
Peer review: yes
URI: http://hdl.handle.net/10773/41299
DOI: 10.1063/1.5114521
ISSN: 0094-243X
Aparece nas coleções: CIDMA - Artigos
FAAG - Artigos
RISCO - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
450054_1_online.pdf476.27 kBAdobe PDFVer/Abrir


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.