Utilize este identificador para referenciar este registo: http://hdl.handle.net/10773/22737
Título: Application of dispersive liquid–liquid microextraction for estrogens׳ quantification by enzyme-linked immunosorbent assay
Autor: Lima, Diana L. D.
Silva, Carla Patrícia
Schneider, Rudolf J.
Otero, Marta
Esteves, Valdemar I.
Palavras-chave: 17α-ethinylestradiol
17β-estradiol
DLLME
ELISA
Environment
Water samples
Data: 2014
Editora: Elsevier
Resumo: Estrogens, such as 17β-estradiol (E2) and 17α-ethinylestradiol (EE2), are the major responsible for endocrine-disrupting effects observed in aquatic environments due to their high estrogenic potency, even at concentrations ranging from pgL(-1) to ng L(-1). Thus, it is essential to develop analytical methodologies suitable for monitoring their presence in water samples. Dispersive liquid-liquid microextraction (DLLME) was used as a pre-concentration step prior to the quantification of E2 and EE2 by enzyme-linked immunosorbent assay (ELISA). First, an evaluation of the effect of DDLME on the E2 and EE2 ELISA calibration curves was performed. Since the extraction procedure itself had an influence on the ELISA optical density (OD), it became necessary to subject, not only the samples, but also all the standards to the DLLME process. Working ranges were determined, being between 1.2 and 8000 ng L(-1), for E2, and between 0.22 and 1500 ng L(-1), for EE2. The influence of organic matter, both in the extraction and quantification, was evaluated and it was observed that its presence in the solution did not affect considerably the calibration curve. Recovery rates were also determined, ranging from 77% to 106% for ultrapure water and from 104% to 115% for waste water samples, the most complex ones in what concerns matrix effects. Results obtained when applying the proposed method to real water samples can be considered quite satisfying. Moreover, the obtained working ranges encompass values generally reported in literature, confirming the practical use of the method for environmental samples.
Peer review: yes
URI: http://hdl.handle.net/10773/22737
DOI: 10.1016/j.talanta.2014.02.069
ISSN: 0039-9140
Aparece nas coleções: CESAM - Artigos
DQ - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Lima et al. - 2014 - Application of dispersive liquid-liquid microextra.pdf694.03 kBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.