Please use this identifier to cite or link to this item:
http://hdl.handle.net/10773/25525
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Silva, Lurdes I. B. | pt_PT |
dc.contributor.author | Justino, Celine I. L. | pt_PT |
dc.contributor.author | Lopes, Isabel | pt_PT |
dc.contributor.author | Pereira, Ruth | pt_PT |
dc.contributor.author | Freitas, Ana Cristina | pt_PT |
dc.contributor.author | Calado, Ricardo | pt_PT |
dc.contributor.author | Rocha-Santos, Teresa A. P. | pt_PT |
dc.contributor.author | Panteleitchouk, Teresa S. L. | pt_PT |
dc.contributor.author | Pereira, Maria E. | pt_PT |
dc.contributor.author | Duarte, Armando Costa | pt_PT |
dc.date.accessioned | 2019-03-11T14:24:42Z | - |
dc.date.available | 2019-03-11T14:24:42Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 1464-0325 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10773/25525 | - |
dc.description.abstract | A new methodology for the assessment of thiocyanate (SCN−) is proposed based on optical fiber (OF) detection coupled to a liquid chromatography system (LC). The developed methodology showed an adequate performance for the analysis of SCN− comparable to a high performance liquid chromatography with UV detector (HPLC-UV) methodology: a detection limit of 3 µg L−1, a linear range from 4 to 400 µg L−1, and an analytical time of less than 6 min. The OF based methodology was of compact design and easy operation. This simple system has the potential to be used as a sensing approach for SCN− in seawater. | pt_PT |
dc.language.iso | eng | pt_PT |
dc.publisher | Royal Society of Chemistry | pt_PT |
dc.relation | info:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F60429%2F2009/PT | pt_PT |
dc.relation | info:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBPD%2F48028%2F2008/PT | pt_PT |
dc.relation | info:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBPD%2F65410%2F2009/PT | pt_PT |
dc.relation | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/65760/PT | pt_PT |
dc.rights | restrictedAccess | pt_PT |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | pt_PT |
dc.title | Optical fiber based methodology for assessment of thiocyanate in seawater | pt_PT |
dc.type | article | pt_PT |
dc.description.version | published | pt_PT |
dc.peerreviewed | yes | pt_PT |
degois.publication.firstPage | 1811 | pt_PT |
degois.publication.lastPage | 1815 | pt_PT |
degois.publication.title | Journal of Environmental Monitoring | pt_PT |
degois.publication.volume | 13 | pt_PT |
dc.identifier.doi | 10.1039/C1EM10043B | pt_PT |
dc.identifier.essn | 1464-0333 | pt_PT |
Appears in Collections: | CESAM - Artigos DBio - Artigos DQ - Artigos |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Silva et al. - 2011 - Optical fiber based methodology for assessment of .pdf | 163.27 kB | Adobe PDF |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.