Abstract: A produção de efluentes industriais é uma das questões ambientais mais relevantes para as indústrias na medida em que estas são obrigadas a cumprir regulamentos legais onde são estabelecidos valores-limite de emissão na sua descarga. O presente estudo surge no sentido de auxiliar a Schmidt Light Metal, Fundição Injectada, Lda. (SLM) na procura do método mais apropriado para o tratamento dos efluentes nesta produzidos, de modo a cumprir os valores-limite de descarga em coletor, a serem estabelecidos pela INDAQUA Oliveira de Azeméis. Até ao início do presente relatório o tratamento era realizado com membranas de ultrafiltração que, dados os seus 15 anos de funcionamento, necessitavam de ser substituídas. Numa fase inicial foi feito o levantamento de toda a rede de efluentes e foram quantificados os caudais gerados. Seguidamente o efluente foi caraterizado relativamente aos parâmetros pH, carência química de oxigénio (CQO), sólidos suspensos totais e sólidos suspensos voláteis (SST/SSV) e óleos e gorduras em diferentes pontos do circuito. Das análises resultaram valores elevados de CQO, SST/SSV e óleos e gorduras nos locais amostrados o que acentuou a real necessidade de reestruturação da unidade de tratamento existente. Posteriormente foi realizado um ensaio com uma nova membrana de ultrafiltração que permitiu determinar a respetiva capacidade de tratamento do efluente em questão. Nos parâmetros de SST/SSV e óleos e gorduras foi possível atingir valores consideravelmente inferiores aos valores-limite previstos e reduções da ordem dos 90% e 99%, respetivamente, no entanto ao nível da CQO, apesar de uma redução de aproximadamente 46%, este parâmetro apresentou ainda concentrações muito superiores ao valor máximo previsto, para descarga em coletor. A realização de futuros estudos com outras tecnologias de tratamento que substituam ou complementem o tratamento já existente seria importante de forma a SLM conseguir atingir os valores-limite de descarga em coletor a serem impostos pela INDAQUA Oliveira de Azeméis.
The production of industrial wastewater is one of the most important environmental issues for industries considering that they are required to comply with legal regulations where emission limit values are set. This study emerges in order to support Schmidt Light Metal, Fundição Injetada, Lda. (SLM) in studying the most appropriate method for the treatment of the effluents they produce, so that they can meet the limit values for discharge collector to be established by INDAQUA Oliveira de Azeméis. Before this report took place, the treatment was performed with ultrafiltration membranes, which are in need of replacement, because this is a process that has been used for the past 15 years. Firstly, a survey on the entire effluent network was conducted and were quantified flowrates. Secondly, the effluent were characterized considering the values of pH, chemical oxygen demand (COD), total suspended solids and volatile suspended solids (TSS/VSS), oils and greases at various points of the circuit. From this analysis resulted high values of COD, TSS / SSV, oils and greases, which emphasized the real need to restructure the existing treatment plant. Subsequently, a test was completed using a new ultrafiltration membrane, which made possible to determine the respective processing capacity of the effluent in question. In the parameters of SST / SSV, oils and greases it was possible to achieve numbers that were considerably lower than the limit values expected, and a reduction of 90% and 99%, respectively. Nonetheless, as for the COD parameter and despite a reduction of approximately 46%, the levels of concentration were much higher than the maximum value estimated for discharge collector. Studies with other treatment technologies would be important in order to achieve the limit values to be set by INDAQUA Oliveira de Azeméis.
Description: Mestrado em Engenharia do Ambiente
URI: http://hdl.handle.net/10773/22561
Appears in Collections:DAO - Dissertações de mestrado
UA - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
Dissertação.pdfDissertação_JessicaPalma2.9 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.