Utilize este identificador para referenciar este registo: http://hdl.handle.net/10773/20253
Título: Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes
Autor: Valente, Nuno I. P.
Tarelho, Sonia
Castro, Andre L.
Silvestre, Armando
Teixeira, Helena M.
Palavras-chave: CAPILLARY GAS-CHROMATOGRAPHY
SOLID-PHASE MICROEXTRACTION
HUMAN-BODY FLUIDS
TANDEM MASS-SPECTROMETRY
HUMAN SERUM
MULTIRESIDUE DETERMINATION
POSTMORTEM TOXICOLOGY
SAMPLES
CHLORPYRIFOS
EXTRACTION
Data: 2015
Editora: ELSEVIER SCI LTD
Resumo: In the present work, two multi-residue methods for the determination of ten organophosphorus pesticides (OPs), namely chlorfenvinphos, chlorpyrifos, diazinon, dimethoate, fenthion, malathion, parathion, phosalone, pirimiphos-methyl and quinalphos, in post-mortem whole blood samples are presented. The adopted procedure uses GC-MS for screening and quantitation, and GC-mu ECD (electron capture detector) for compound confirmation. Three different Solid Phase Extraction (SPE) procedures for OPs with Oasis (R) hydrophilic lipophilic balanced (HLB) and Sep-Pak (R) C18 cartridges were tested, and followed by GC-mu ECD and GC-MS analysis. The Sep-Pak (R) C18 cartridges extraction procedure was selected since it generated analytical signals 5 times higher than those obtained with the two different Oasis (R) HLB cartridges extraction procedures. The method has shown to be selective for the isolation of selected OPs as well as to the chosen internal standard (ethion) in postmortem blood samples. Calibration curves between 50 and 5000 ng/mL were prepared using weighted linear regression models (1/x(2)). It was not possible to establish a working range for fenthion by GC-mu ECD due to the lower sensitivity of the detector to this compound, whereas for pirimiphos-methyl it was set between 500 and 5000 ng/mL. The limit of quantitation was established at 50 ng/mL for all analytes, except for pirimiphos-methyl by GC-mu ECD analysis (500 ng/mL). The average extraction efficiency ranged from 72 to 102%. The developed methods were considered robust and fit for the purpose, and had already been adopted in the laboratory routine analysis. (C) 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Peer review: yes
URI: http://hdl.handle.net/10773/20253
DOI: 10.1016/j.jflm.2015.03.006
ISSN: 1752-928X
Versão do Editor: 10.1016/j.jflm.2015.03.006
Aparece nas coleções: CICECO - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes_10.1016j.jflm.2015.03.006.pdf674.97 kBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.