Please use this identifier to cite or link to this item:
http://hdl.handle.net/10773/9804
Title: | Funcionalização de argamassas para controlo das condições ambiente |
Author: | Vieira, João Emanuel Ramos |
Advisor: | Batista, João António Labrincha Ferreira, Victor Miguel Carneiro de Sousa |
Keywords: | Engenharia de materiais Argamassas Revestimento de paredes Nanomateriais Qualidade do ar interior: Edifícios |
Defense Date: | 2012 |
Publisher: | Universidade de Aveiro |
Abstract: | Nos últimos anos tem crescido a preocupação em termos ambientais e
económicos, por parte das indústrias e das pessoas em geral. O sentimento de
conforto depende muitas vezes do uso de aparelhos auxiliares, que consomem
combustíveis fósseis. Para além do preço tendencialmente crescente destas
fontes de energia, também resultante da menor disponibilidade e futura
escassez, há hoje preocupações com as emissões de gases de estufa (ex.
CO2). Por isso, ganham relevo formas passivas de ajustar a temperatura e
humidade relativa de ambientes interiores, onde as pessoas passam cada vez
mais tempo ao longo da vida, ao mesmo tempo que se procuram soluções de
limpeza e desinfeção do ar que se respira.
Neste trabalho estudou-se o efeito da incorporação de adjuvantes numa
argamassa padrão de cimento e cal aérea usada no revestimento de paredes
interiores de edifícios. Foi avaliado o desempenho da incorporação de
poliacrilato de sódio (PA), materiais de mudança de fase (PCM) e de
nanopartículas de dióxido de titânio (TiO2), respetivamente em funções de
modulação de humidade, temperatura e na oxidação de NOx. Para além da
incorporação individual de cada um daqueles agentes, testaram-se diferentes
combinações dos três adjuvantes e distintas percentagens de PA. Foi também
avaliada a influência que a incorporação daqueles materiais causa em
propriedades comuns das argamassas, tanto no estado fresco (% de ar
incluído e comportamento reológico) como após endurecimento (resistência
mecânica, coeficiente de capilaridade, condutividade térmica, módulo de
elasticidade).
Com a realização deste trabalho foi possível obter uma degradação de NOx
próxima de 42%, nas amostras com 1% (em massa) de TiO2. Verificou-se a
atenuação na oscilação da temperatura em 2-3°C, em amostras contendo
20% de PCM, sobretudo por redução dos valores mínimos atingidos. Além
disso, a variação térmica é retardada. As amostras com PA na sua constituição
sujeitas a ensaio de MBV (método de Nordtest) atingem a classificação de
Bom (1-2 g/(m2.%HR)), não havendo acentuada perda de capacidade quando
o material é revestido com uma camada de tinta. No entanto requer controlo
especial a tendência expansiva (inchamento) revelada pelas amostras
contendo combinações de PCM e PA, detetada durante os ensaios de
capilaridade e de saturação de água. Este problema acarreta degradação da
resistência mecânica e indesejáveis efeitos estéticos superficiais.
Relativamente às amostras mais promissoras sugere-se a realização de
estudos de durabilidade. In recent years there has been a growing concern on environmental and energy demand to produce the building materials, as well during their use. At the same time, actual human living conditions correspond to occupation of interior spaces for a growing time. Requirements of increasing comfort and indoor air quality are obvious and the use of auxiliary devices that consume fossil fuels is more and more common. Reduced availability of fossil fuels and concerns about emissions of greenhouse gases (e.g. CO2) induced the search for solutions of passive control and modulation of distinct indoor variables. This work studies the development of novel low impact vapour permeable mortars (internal walls) to control and passively regulate indoor environmental air pollutants, moisture and temperature, to provide improved comfort and health of building occupants. Several functional additions were added to an industrial lime-based mortar: (i) sodium polyacrylate (PA) superabsorbent, phase change materials (PCM) and titanium dioxide (TiO2) photocatalytic nanoparticles, attempting to (respectively) regulate indoor moisture and temperature values, while reducing the NOx concentration. Besides the use of each individual addition, distinct combinations of two or three components were tested. Their effects on the novel functions were determined, while the control of common properties was also performed, including fresh state (% air included and rheological behavior) and hardened (mechanical strength, elasticity modulus, density, capillarity coefficient, thermal conductivity, etc) properties. Samples containing 1 wt% TiO2 degraded about 42% NOx on repetitive trials. The amplitude of temperature variation was reduced on 2-3 °C by samples containing 20 wt% PCM. Furthermore, the temperature variation is retarded. Samples with 1-1.5 wt% PA were classed as Good (1-2 g/(m2.% RH)) upon determinations of MBV values by the Nordtest method. The surface painting did not strongly affect the absorbing performance. The main problem was detected on samples containing PCM and PA combinations after performing capillary and water saturation tests, denoted by an expressive swelling. This expansive occurrence tends to degrade the mechanical strength of samples while created unpleasant aesthetical effects. For the most promising samples further durability tests should be conducted. This work helped to develop knowledge and optimised solutions to facilitate the wider use of novel hygro-thermal eco-materials by the construction industry. |
Description: | Mestrado em Engenharia de Materiais |
URI: | http://hdl.handle.net/10773/9804 |
Appears in Collections: | UA - Dissertações de mestrado DEMaC - Dissertações de mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
dissertação.pdf | 16.04 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.