Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/34343
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFurtado, Andrépt_PT
dc.contributor.authorArêde, Antóniopt_PT
dc.contributor.authorRodrigues, Hugopt_PT
dc.date.accessioned2022-07-27T14:02:19Z-
dc.date.available2022-07-27T14:02:19Z-
dc.date.issued2022-10-
dc.identifier.issn1090-0268pt_PT
dc.identifier.urihttp://hdl.handle.net/10773/34343-
dc.description.abstractThe existing infilled reinforced concrete (RC) buildings' poor energy performance is responsible for a significant part of the energy consumption in the European Union (EU). In addition, recent earthquakes showed the seismic vulnerability of the existing RC buildings that were not designed according to modern codes, where several casualties, collapses, and economic losses were reported. Around 40% of the EU buildings are located in seismic regions and designed with substandard safety requirements, of which 65% need both energy and seismic retrofit. New strategies are necessary to simultaneously improve the energy efficiency and seismic vulnerability of new constructions. Apart from the modern seismic and energy codes, new materials are being developed by the construction industry that can play a significant role in the next few decades. Based on this motivation, this paper aims to study the efficiency of using textile-reinforced mortar (TRM)-based solutions to improve the seismic behavior of masonry infill walls made of lightweight and energy-improved masonry blocks. This holistic strategy is designed for new constructions. For this, eight strengthened energy-improved infill walls were subjected to flexural strength tests to validate the TRM efficiency using a low-strength and a high-strength textile mesh and study the effect of using connectors. All the tests consisted of applying a monotonic out-of-plane tests were performed through a one-point load approach. The results will be presented in terms of out-of-plane force-displacement responses, flexural stress, and damage evolution. Lastly, a state-of-the-art discussion is carried out to analyze possible relationships between the textile mesh tensile strength and the flexural strength of the wallspt_PT
dc.language.isoengpt_PT
dc.publisherASCEpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04708%2F2020/PTpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F04708%2F2020/PTpt_PT
dc.relationUIDB/ECI/04450/2020pt_PT
dc.rightsrestrictedAccesspt_PT
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectExperimental testingpt_PT
dc.subjectFlexural strength testspt_PT
dc.subjectLightweight concrete blockspt_PT
dc.subjectMasonry infill wallspt_PT
dc.subjectOut-of-plane behaviorpt_PT
dc.subjectTRM strengtheningpt_PT
dc.titleThe effect of a textile-reinforced mortar on the flexural response of energy-improved infill wallspt_PT
dc.typearticlept_PT
dc.description.versionpublishedpt_PT
dc.peerreviewedyespt_PT
degois.publication.issue5pt_PT
degois.publication.titleJournal of Composites for Constructionpt_PT
degois.publication.volume26pt_PT
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0001237pt_PT
dc.identifier.essn1943-5614pt_PT
dc.identifier.articlenumber04022047pt_PT
Appears in Collections:DECivil - Artigos
RISCO - Artigos

Files in This Item:
File Description SizeFormat 
JCC_Strengthened wallets.pdf3.78 MBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.