Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/27739
Title: Seasonal evaluation of outdoor/indoor air quality in primary schools in Lisbon
Author: Pegas, P. N.
Alves, C. A.
Evtyugina, M. G.
Nunes, T.
Cerqueira, M.
Franchi, M.
Pio, C. A.
Almeida, S. M.
Verde, S. Cabo
Freitas, M. C.
Issue Date: Mar-2011
Publisher: Royal Society of Chemistry
Abstract: The aim of this study was to evaluate the indoor (I) and outdoor (O) levels of NO₂, speciated volatile organic compounds (VOCs) and carbonyls at fourteen primary schools in Lisbon (Portugal) during spring, autumn and winter. Three of these schools were also selected to be monitored for comfort parameters, such as temperature and relative humidity, carbon dioxide (CO₂), carbon monoxide (CO), total VOCs, and both bacterial and fungal colony-forming units per cubic metre. The concentration of CO₂ and bioaerosols greatly exceeded the acceptable maximum values of 1800 mg m⁻³ and 500 CFU m⁻³, respectively, in all seasons. Most of the assessed VOCs and carbonyls occurred at I/O ratios above unity in all seasons, thus showing the importance of indoor sources and building conditions in indoor air quality. However, it has been observed that higher indoor VOC concentrations occurred more often in the colder months, while carbonyl concentrations were higher in the warm months. In general, the I/O NO₂ ratios ranged between 0.35 and 1, never exceeding the unity. Some actions are suggested to improve the indoor air quality in Lisbon primary schools.
Peer review: yes
URI: http://hdl.handle.net/10773/27739
DOI: 10.1039/c0em00472c
ISSN: 1464-0325
Appears in Collections:CESAM - Artigos
DAO - Artigos

Files in This Item:
File Description SizeFormat 
Pegas et al. - 2011 - Seasonal evaluation of outdoorindoor air quality .pdf475.77 kBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.