Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/23278
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMartins, Nelson Amadeu Diaspt
dc.contributor.authorChaves, Mariana Ramospt
dc.date.accessioned2018-05-28T11:33:23Z-
dc.date.available2018-05-28T11:33:23Z-
dc.date.issued2017-12-
dc.identifier.urihttp://hdl.handle.net/10773/23278-
dc.descriptionMestrado em Sistemas Energéticos Sustentáveispt
dc.description.abstractO objetivo principal deste projeto é realizar uma avaliação energética de uma fração do edifício de escritórios e armazéns, onde se encontra a empresa Sondar.i, no Centro Empresarial da Gafanha da Nazaré, em Ílhavo e dimensionar um sistema de climatização apropriado que substitua os aquecedores a óleo e halogéneo, atualmente responsáveis pela climatização na estação de aquecimento. No presente trabalho de projeto são avaliados os consumos efetivos energéticos da Sondar.i, obtidos a partir do levantamento dos equipamentos instalados, da potência de cada equipamento e os respetivos perfis de utilização e é criado um modelo do edifício no software Designbuilder® para avaliar o comportamento de diferentes sistemas de climatização que se pretende estudar. São avaliados dois sistemas de climatização para três diferentes níveis de climatização: aquecimento; aquecimento e arrefecimento; e aquecimento, arrefecimento e ventilação mecânica. Dos sistemas avaliados é sugerido a implementação do sistema com a bomba de calor pois apresenta menor consumo energético e instalação mais apelativa.pt
dc.description.abstractThe main objective of this project is to carry out an energy evaluation of a fraction of the office and warehouse building, where the company Sondar.i is located, in the Business Center of Gafanha da Nazaré, in Ílhavo and design an appropriate air conditioning system that replaces the heaters oil and halogen, currently responsible for air conditioning in the heating season. In the present project work the actual energy consumption of Sondar.i, obtained from the surveying of the installed equipment, the power of each equipment and the respective utilization profiles, is evaluated, and a building model is created in the Designbuilder® software to evaluate the behaviour of different air conditioning systems to be studied. Two air conditioning systems are evaluated for three different levels of air conditioning: heating; heating and cooling; and heating, cooling and mechanical ventilation. From the evaluated systems, it is suggested to implement the system with the heat pump because it presents less energy consumption and more appealing installation.pt
dc.language.isoporpt
dc.publisherUniversidade de Aveiropt
dc.rightsopenAccesspor
dc.subjectSistemas energéticos sustentáveispt
dc.subjectEdifícios industriais: Consumo de energiapt
dc.subjectClimatizaçãopt
dc.subjectEficiência energéticapt
dc.subject.otherSimulação dinâmicapt
dc.subject.otherDesignBuilderpt
dc.subject.otherAnálise energéticapt
dc.subject.otherEficiência energéticapt
dc.titleAnálise energética e avaliação de sistema AVAC no sede da empresa Sondar.ipt
dc.typemasterThesispt
thesis.degree.levelmestradopt
thesis.degree.grantorUniversidade de Aveiropt
dc.identifier.tid201945355-
Appears in Collections:DAO - Dissertações de mestrado
UA - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
Dissertação.pdf2.85 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.