dc.description.abstractO principal objetivo deste trabalho consistiu em avaliar a possibilidade de utilizar um número reduzido de ficheiros climáticos para a análise do desempenho energético de edifícios em todo o território nacional (continental). Para o efeito foi desenvolvido e ensaiado um procedimento destinado ao cálculo dos consumos nominais de um edifício em Portugal, utilizando ficheiros climáticos de apenas seis cidades, por oposição à exigência regulamentar em vigor que prevê a utilização de ficheiros climáticos com uma resolução ao nível do concelho. Deverá ser salientado que os seis ficheiros climáticos acima referidos estão normalmente disponíveis de forma gratuita, integrados na generalidade das aplicações computacionais existentes para simulação dinâmica de edifícios ao contrário dos ficheiros climáticos ao nível do concelho. Acresce que nalguns casos é inviável a utilização destes últimos devido a incompatibilidade entre o software de simulação e os ficheiros disponíveis (Solterm/LNEG) A solução proposta para este problema passou por, através de uma metodologia de cálculo simplificada, estabelecer fatores de correção aplicáveis aos seis concelhos referência, de modo a partir destes obter os consumos energéticos para qualquer concelho de Portugal continental. Da comparação dos resultados obtidos com a metodologia proposta com a convencional, conclui-se que esta produz resultados aceitáveis em determinados concelhos do país, contudo tal não significa que não existam desvios. A metodologia proposta apresentou algumas fragilidades, não tendo sido possível estabelecer um procedimento que garantisse sucesso de forma generalizada. Ainda assim não ficou claro se tal se deve a desvios não explicados ao nível dos ficheiros climáticos utilizados, ou se é uma impossibilidade intrínseca ao método, pelo que será necessário aprofundar o estudo aqui iniciado.pt
dc.description.abstractThe main objective of this study was to evaluate the possibility of to analyze of the energy performance of buildings around the country (mainland) using a reduced number of weather files. For this purpose it was developed and tested a procedure aiming the calculation of the energy consumption of a building in Portugal, using weather files limited to six major cities, in opposition to the current regulatory requirement that requires the use of weather files with a resolution to the county level. It should be noted that the six aforementioned weather files are usually available for free, integrated in most of the existing computer applications for dynamic simulation of buildings unlike the above mentioned county level weather files. Moreover, in some cases it is impractical to use the latter due to their incompatibility with the simulation software. The proposed solution is based on the use of energy consumption correction factors, determined through a simplified calculation methodology, which are applied to the six reference cities (locations) in order to obtain from these the energy consumption for any municipality of Portugal. Comparing the obtained results with the proposed methodology and the conventional one, it may be concluded that it produces acceptable results in certain districts of the country, however, this does not mean that there are no deviations. In fact, the proposed methodology showed some weaknesses, it was not possible to establish a procedure that would guarantee a general success. Still it is not clear whether this is due to unexplained deviations within the county level weather files used, or whether it is a impossibility intrinsic to the proposed methodology, therefore further work will be required to clearly understand the identified deviations.pt
dc.language.isoporpt
dc.publisherUniversidade de Aveiropt
dc.rightsopenAccesspor
dc.subjectEngenharia mecânicapt
dc.subjectZonas climáticas: Portugalpt
dc.subjectBalanço energético: Edifícios: Portugalpt
dc.subjectEficiência energética: Edifícios: Portugalpt
dc.subjectConsumo de energia: Edifícios: Portugalpt
dc.titleZonamento climático e regulamentação energética: o caso portuguêspt
dc.typemasterThesispt
thesis.degree.levelmestradopt
thesis.degree.grantorUniversidade de Aveiropt