Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/6106
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCompleto, A.pt
dc.contributor.authorPereira, J.pt
dc.contributor.authorFonseca, F.pt
dc.contributor.authorRamos, A.pt
dc.contributor.authorRelvas, C.pt
dc.contributor.authorSimões, J.pt
dc.date.accessioned2012-02-09T14:50:28Z-
dc.date.issued2011-
dc.identifier.issn0268-0033pt
dc.identifier.urihttp://hdl.handle.net/10773/6106-
dc.description.abstractBackground: Numerous models of elbow prostheses are being used and can be divided into two categories: one being a semi-constrained, linked type; and the other being non-constrained, unlinked type. Recent reports of National Elbow Arthroplasty Registers reveal no significant differences in the survival rates between linked and unlinked prosthesis brands, and the main cause appointed for revision for both types is loosening. Some previous biomechanical studies confirm the presence of abnormal bone stresses for the linked type, which can be associated with the risk of loosening. However for the unlinked type, biomechanical studies are not available that corroborate a loosening risk. It seems, that issue has not yet been fully answered and requires further analysis. Methods: Cortex strains adjacent to the elbow joint were measured with strain gauges in synthetic humeri and ulnae, before and after replacement. To assess cancellous bone strains and cement stresses around the implant finite element models validated relative to measured strains were used. Findings: Bone strains adjacent to the implant tip increased several times in the humerus and ulna. At the epiphyseal regions a generalised cancellous bone strain reduction was observed for both humerus and ulna relatively to the intact bones. Interpretation: The unlinked elbow prostheses can be associated with the risk of bone fatigue failure by overload, particularly in the ulna, and bone resorption by stress-shielding at the epiphyseal regions. The identical structural behaviour relative to linked prostheses associated with the same loosening risks corroborates the results of recent arthroplasty published register reports.pt
dc.language.isoengpt
dc.relation.urihttp://www.scopus.com/inward/record.url?eid=2-s2.0-80055096546&partnerID=40&md5=7be56be57d062815cb83223c1a2bda9c
dc.rightsrestrictedAccesspor
dc.subjectInstrumented Bone Preservingpt
dc.subjectUnlinked elbow prosthesispt
dc.subjectStrain gaugespt
dc.subjectFinite element modelspt
dc.titleBiomechanical analysis of total elbow replacement with unlinked iBP prosthesis: an in vitro and finite element analysispt
dc.typearticlept
dc.peerreviewedyespt
ua.distributioninternationalpt
degois.publication.firstPage990pt
degois.publication.issue10pt
degois.publication.issue10
degois.publication.lastPage997pt
degois.publication.titleClinical Biomechanicspt
degois.publication.volume26pt
dc.date.embargo10000-01-01-
dc.identifier.doi10.1016/j.clinbiomech.2011.06.008*
Appears in Collections:DEM - Artigos

Files in This Item:
File Description SizeFormat 
2011_Biomechanical analysis of total elbow replacement with unlinked iBP prosthesis.pdfcópia final1.37 MBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.