Please use this identifier to cite or link to this item:
http://hdl.handle.net/10773/4827
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Pereira, Luiz Fernando Ribeiro | - |
dc.contributor.author | Castro, Ângelo Filipe Ramos Freitas de | pt |
dc.coverage.spatial | Aveiro | pt |
dc.date.accessioned | 2011-12-27T15:23:54Z | - |
dc.date.available | 2011-12-27T15:23:54Z | - |
dc.date.issued | 2007 | pt |
dc.identifier.uri | http://hdl.handle.net/10773/4827 | - |
dc.description | Mestrado em Física Aplicada | pt |
dc.description.abstract | O presente trabalho foca a utilização do aminoácido alanina como potencial dosímetro de controle em radioterapia. O conceito é baseado na facto de ser conhecida a linearidade entre a dose de radiação absorvida pela alanina e o seu sinal de ressonância paramagnética electrónica (EPR), permitindo desta forma o uso do material para controle dosimétrico de alta dose, embora com alguma limitação quando a dose é baixa. Nesta sequência, este trabalho estudou a aplicação da alanina como dosímetro de radioerapia, mas numa região de relativa baixa dose. A fim de se obter correctamente a dose absorvida, foi aplicada um novo método de reconstrução teórica dos espectros de EPR. A sua aplicabilidade foi testada no plano (2D) e em volume (3D), após a obtenção da respectiva curva de calibração. Os resultados mostram uma boa precisão, sugerindo uma fiável aplicação como controle dosimétrico em radioterapia. | pt |
dc.description.abstract | This work focuses the use of alanine aminoacid as a potential dosimeter in radiotherapy control. The basis of this use is the very well known linearity between the alanine absorbed dose and the electron paramagnetic resonance (EPR) signal, allowing thus, the material use to dosimetric control under high radiation dose. However, this technique exhibits limitations at low dose absorption. Considering that problem, this work was studied the alanine application as low dose dosimeter in radiotherapy. In order to obtain the correct value of absorbed dose, a new method for theoretical EPR spectra reconstruction was applied. Its viability was tested under a planar (2D) and volumic (3D) configuration. The results shows that a good precision can be achieved, suggesting that can be applied as dosimetric radiotherapy control. | pt |
dc.language.iso | por | pt |
dc.publisher | Universidade de Aveiro | pt |
dc.relation.uri | http://opac.ua.pt/F?func=find-b&find_code=SYS&request=000212687 | pt |
dc.rights | openAccess | por |
dc.subject | Física aplicada | pt |
dc.subject | Radioterapia | pt |
dc.subject | Ressonância paramagnética electrónica | pt |
dc.subject | Radiação | pt |
dc.title | Aplicação da dosiometria de alanina/EPR na radioterapia | pt |
dc.type | masterThesis | pt |
thesis.degree.level | Mestrado | pt |
thesis.degree.grantor | Universidade de Aveiro | pt |
Appears in Collections: | UA - Dissertações de mestrado DFis - Dissertações de mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2008000095.pdf | 1.95 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.