Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/35494
Title: Test-retest reliability, agreement and construct validity of the International Physical Activity Questionnaire short-form (IPAQ-sf) in people with COPD
Author: Flora, Sofia
Marques, Alda
Hipólito, Nádia
Morais, Nuno
Silva, Cândida G.
Januário, Filipa
Rodrigues, Fátima
Carreira, Bruno P.
Cruz, J.
Keywords: Accelerometer
Chronic obstructive pulmonary disease
Physical activity
Psychometric properties
Validation study
Issue Date: Jan-2023
Publisher: Elsevier
Abstract: This study assessed the test-retest reliability/agreement and construct validity of the International Physical Activity Questionnaire short-form (IPAQ-sf) in patients with chronic obstructive pulmonary disease (COPD). It also explored differences in its validity according to age, sex and GOLD airflow obstruction levels. 62 participants (68 ± 8 years, 53 males, FEV1 51 ± 23%pred) completed the Portuguese IPAQ-sf, wore an accelerometer for 7 days and completed a second IPAQ-sf. Test-retest reliability/agreement was assessed with Intraclass Correlation Coefficient (ICC2,1), 95% Limits of Agreement (LoA), standard error of measurement (SEM) and minimal detectable change (MDC95) for continuous variables, and percentage of agreement (%agreement) for categories (“active”/“inactive”). Validity was assessed with 95% LoA and Spearman's correlations (ρ) between IPAQ-sf 2 (METs-min/week, time in vigorous [VPA], moderate PA [MPA] and walking) and accelerometry (time in MVPA, VPA, MPA and step counts) for continuous variables; %agreement, Cohen's kappa, and sensitivity specificity and±predictive values for categories. Correlations were also performed for age, sex and GOLD airflow obstruction grades. Reliability was good (ICC2,1 = 0.707) with wide LoA (-6446—6409 METs-min/week). SEM and MDC95 were 1840 and 4971 METs-min/week, respectively. %agreement between the two IPAQ-sf was 84% (kappa = 0.660). Positive, moderate and significant correlations were found between IPAQ-sf and accelerometry (0.396 ≤ ρ ≤ 0.527, p < 0.001), except for VPA (p > 0.05). The strongest correlations were found in age (<65 years) and male (0.466 ≤ ρ ≤ 0.653, p < 0.05). %agreement between tools was 65% (kappa = 0.313), with high sensitivity (0.830) but low specificity (0.500). The IPAQ-sf seems valid to be used in COPD but caution on its widespread use is recommended as its accuracy may be limited.
Peer review: yes
URI: http://hdl.handle.net/10773/35494
DOI: 10.1016/j.rmed.2022.107087
ISSN: 0954-6111
Appears in Collections:Lab3R - Artigos



FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.