Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/21656
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorPereira, Maria Eduarda da Cunhapt
dc.contributor.advisorCarvalho, Linapt
dc.contributor.authorMatos, Ana Teresa Marques dept
dc.date.accessioned2018-01-22T15:08:48Z-
dc.date.available2018-01-22T15:08:48Z-
dc.date.issued2015-
dc.identifier.urihttp://hdl.handle.net/10773/21656-
dc.descriptionMestrado em Biotecnologia - Biotecnologia Industrial e Ambientalpt
dc.description.abstractO presente trabalho propõe-se contribuir para melhorar o método de quantificação dos metais alumínio, chumbo, cobre, ferro e níquel em águas de consumo humano na empresa A.Logos. A melhoria testada foi a diminuição do número de leituras de padrões e amostras, reduzindo o tempo e os custos associados a esta análise. No trabalho serão abordadas temáticas relativas à água destinada ao consumo humano, à sua contaminação por metais e consequências desta, que permitem evidenciar a importância do controlo de qualidade de águas e da obrigatoriedade do mesmo por lei. Foi efetuado um estudo de verificação do método de quantificação de metais em águas de consumo humano por espetrofotometria de absorção atómica com atomização em câmara de grafite, método utilizado na empresa A.Logos, comparando os resultados obtidos quando padrões e amostras são analisadas com 3 leituras e com 1 leitura. Para efetuar o estudo de verificação do método, foram avaliados os seguintes parâmetros: curva de calibração, limites de deteção e quantificação, análise de brancos, repetibilidade, análise de duplicados, ensaios de recuperação, erro relativo associado aos padrões de controlo e foram efetuadas análises de amostras de águas de consumo humano. Concluiu-se que apesar de uma possível diminuição da sensibilidade e da precisão do método quando se diminui de 3 para 1 o número de leituras, continuam a ser assegurados os critérios de controlo de qualidade estabelecidos pela empresa A.Logos. Assim, é possível diminuir de 3 para 1 o número de leituras realizado na quantificação de metais em águas de consumo humano por espetrofotometria de absorção atómica, ainda que seja conveniente obter mais dados de histórico para validar esta hipótese.pt
dc.description.abstractThis work aimed to contribute to the improvement of the quantification method of the metals aluminum, lead, copper, iron and nickel in drinking water in A.Logos company. The improvement tested was the reduction of the number of readings used in the analysis of standards and samples, reducing the time and costs associated with this method. The work will address issues relating to water intended for human consumption, its metal contamination and consequences of which reflect the importance of water quality monitoring, mandatory by law. A verification study was done to the method of quantification of metals in drinking water used in A.Logos company by atomic absorption spectrophotometry with graphite atomization chamber, comparing the results obtained for this method when using 3 readings per sample or just 1 reading, for several parameters: calibration curve, detection and quantification limits, blanc analysis, repeatability, duplicate analysis, recovery experiments, control by standards and samples analysis. It was concluded that despite a possible decrease in sensitivity and the correctness of the method linked to the reduction of the number of readings per standard and sample, the quality control criteria established by the company continued to be assured. Thus, it is possible to decrease from 3 to 1 the number of readings performed in the quantification of metals in drinking water by atomic absorption spectrophotometry, although it is more convenient to obtain more historical to validate this hypothesis.pt
dc.language.isoporpt
dc.publisherUniversidade de Aveiropt
dc.rightsopenAccesspor
dc.subjectMetaispt
dc.subjectBiotecnologia industrial e ambientalpt
dc.subjectÁgua potávelpt
dc.subjectEspectroscopia de absorção atómicapt
dc.subjectAnálise da águapt
dc.subject.otherÁguas para consumo humanopt
dc.subject.otherControlo de qualidadept
dc.subject.otherEspectrofotometria de absorção atómica em câmara de grafitept
dc.subject.otherMetaispt
dc.subject.otherMelhoria métodopt
dc.titleImplementação de melhorias na quantificação de metais em água na empresa A. Logospt
dc.typemasterThesispt
thesis.degree.levelmestradopt
thesis.degree.grantorUniversidade de Aveiropt
dc.identifier.tid201027780-
Appears in Collections:UA - Dissertações de mestrado
DQ - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
Tese_Ana Matos.pdf1.64 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.