Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/19792
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRodrigues, Simone P.pt
dc.contributor.authorPaiva, Jose M.pt
dc.contributor.authorDe Francesco, Silviapt
dc.contributor.authorAmaral, Margarida I.pt
dc.contributor.authorOliveira, Filipe J.pt
dc.contributor.authorSilva, Rui F.pt
dc.date.accessioned2017-12-07T19:24:58Z-
dc.date.issued2013pt
dc.identifier.issn0957-4530pt
dc.identifier.urihttp://hdl.handle.net/10773/19792-
dc.description.abstractCommercial femoral head prostheses (cobalt-chromium alloy, yttria partially stabilized zirconia (Y-PSZ) and alumina) and new silicon nitride ceramic ones (nanocrystalline diamond coated and uncoated) were compared in terms of artifact level production by computed tomography (CT). Pelvis examination by CT allows the correct diagnosis of some pathologies (e.g. prostate and colon cancer) and the evaluation of the prosthesis-bone interface in post-operative joint surgery. Artifact quantification is rarely seen in literature despite having a great potential to grade biomaterials according to their imaging properties. Materials' characteristics (density and effective atomic number), size and geometry of the prostheses can cause more or less artifact. A quantification procedure based on the calculation of four statistical parameters for the Hounsfield pixel values (mean, standard deviation, mean squared error and worst case error) is presented. CT sequential and helical scanning modes were performed. Results prove the artifact reproducibility and indicate that the cobalt-chromium and Y-PSZ are the most artifact-inducing materials, while alumina and silicon nitride (diamond coated and uncoated) ceramic ones present a low level of artifact. Considering the excellent biocompatibility and biotribological behaviour reported in earlier works, combined with the high medical imaging quality here assessed, diamond coated silicon nitride ceramics are arising as new materials for joint replacement.pt
dc.language.isoengpt
dc.publisherSPRINGERpt
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBPD%2F26787%2F2006/PTpt
dc.relationinfo:eu-repo/grantAgreement/FCT/COMPETE/132936/PTpt
dc.rightsrestrictedAccesspor
dc.subjectALTERNATIVE MATERIALSpt
dc.subjectRECONSTRUCTIONpt
dc.subjectCYTOTOXICITYpt
dc.subjectRADIOTHERAPYpt
dc.subjectREDUCTIONpt
dc.subjectIMPLANTSpt
dc.titleArtifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement materialpt
dc.typearticlept
dc.peerreviewedyespt
ua.distributioninternationalpt
degois.publication.firstPage231pt
degois.publication.issue1pt
degois.publication.lastPage239pt
degois.publication.titleJOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINEpt
degois.publication.volume24pt
dc.date.embargo10000-01-01-
dc.relation.publisherversion10.1007/s10856-012-4778-0pt
dc.identifier.doi10.1007/s10856-012-4778-0pt
Appears in Collections:CICECO - Artigos



FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.