Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/38379
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMatos, Maria Assunção Coelhopt_PT
dc.contributor.authorCosta, Isabel Maria Monteiropt_PT
dc.contributor.authorPortinha, Raquel Carmopt_PT
dc.contributor.authorAfonso, Beatriz Costapt_PT
dc.contributor.authorBarbosa, Katia Coimbrapt_PT
dc.contributor.authorGouveia, Carla Sofia Limapt_PT
dc.contributor.authorSá-Couto, Pedro Miguel Ferreirapt_PT
dc.date.accessioned2023-07-05T14:23:42Z-
dc.date.available2023-07-05T14:23:42Z-
dc.date.issued2023-04-28-
dc.identifier.issn2184-5794pt_PT
dc.identifier.urihttp://hdl.handle.net/10773/38379-
dc.description.abstractObjective: To contribute to the translation of the self-administered ALSFRS-R - European Portuguese version (ALSFRS-R: EP), and to analyse its reliability to enable its use by ALS patients in Portugal. Methods: The study was developed in 3 phases. Phase 1: Translation and cultural adaptation of the self-administered ALFRS-R; Phase 2: Content validation by study participants; Phase 3: Exploratory factor analysis (EFA), analysis of its internal consistency and test-retest reliability. Results: According to a panel of experts (N=6), a CVI of 100% were obtained for all ALSFRS-R: EP items. A sample of 18 people with ALS (13 male) fulfilled the test and evaluated its items regarding its clarity, comprehension, difficulty, and relevance, obtaining values varying from 8.6 and 8.9, 8.7 and 8.9, 8.5 and 8.8, and 8.5 and 8.9, respectively. The EFA revealed three factors representing the following domains: (1) bulbar function; (2) fine and gross motor function; and (3) respiratory function. The instrument total score and its subscales presented good internal consistency (Cronbach'sα: ranging from 0.72 to 0.92 in the test; from 0.70 to 0.95 in the retest) and good to excellent test-retest reliability (Kendall tau: ranging from 0.58 to 0.99). Considering the scale total score for the test, no statistical differences were observed between females and males nor between bulbar ALS and medullar ALS. The correlation between the total score and age showed to be significant and negative (-0.53). Conclusions: The Self-Administered ALSFRS-R: EP version was successfully translated, validated, and presented good to excellent reliability results, with similar EFA structure to other studies. It will allow its use by European Portuguese ALS patients, enabling their health professionals to monitor the disease progression at home.pt_PT
dc.language.isoengpt_PT
dc.publisherUniversity of Aveiropt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04106%2F2020/PTpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F04106%2F2020/PTpt_PT
dc.rightsopenAccesspt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectAmyotrophic lateral sclerosispt_PT
dc.subjectSelf-administered ALSFRS-Rpt_PT
dc.subjectFunctionalitypt_PT
dc.subjectQuality of lifept_PT
dc.titleContribution to the translation and reliability analysis of the Self-Administered Amyotrophic Lateral Sclerosis Functional Rating Scale - revised, for european portuguesept_PT
dc.typearticlept_PT
dc.description.versionpublishedpt_PT
dc.peerreviewedyespt_PT
degois.publication.issue1pt_PT
degois.publication.titleJournal of Statistics in Health Decisionpt_PT
degois.publication.volume5pt_PT
dc.identifier.doi10.34624/jshd.v5i1.28483pt_PT
dc.identifier.articlenumbere28483pt_PT
Appears in Collections:ESSUA - Artigos
CINTESIS - Artigos

Files in This Item:
File Description SizeFormat 
28483-Manuscript Body-78556-1-10-20230428.pdf839.99 kBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.