Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/8793
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorVila Real, Paulopt
dc.contributor.advisorLopes, Nuno Filipe Ferreira Soares Borgespt
dc.contributor.authorLomba, Nilton César Fernandes dapt
dc.date.accessioned2012-07-23T13:35:09Z-
dc.date.available2012-07-23T13:35:09Z-
dc.date.issued2011-
dc.identifier.urihttp://hdl.handle.net/10773/8793-
dc.descriptionMestrado em Engenharia Civilpt
dc.description.abstractAo longo do tempo são inúmeras e irreparáveis as perdas humanas e de património que têm vindo a suceder devido aos incêndios. O betão armado é dos materiais mais utilizados nas construções atualmente. A certa imprevisibilidade de um incêndio associada a sua danosa influência na resistência desse material tornam imprescindível o estudo do comportamento de peças estruturais de betão armado em situação de incêndio, bem como o desenvolvimento de ferramentas de verificação da resistência dessas peças para os vários tempos de resistência ao fogo regulamentares. Os estudos desses danos começaram com mais intensidade a partir de 1968, após a ruína parcial do prédio da Ronan Point na periferia de Londres causada pela explosão de uma botija de gás e o seu imediato desabamento. Em Portugal só se despertaram para os impactos do incêndio nas vidas das pessoas e dos patrimónios anos depois, em 1988 após o grande incêndio dos armazéns do chiado na baixa de lisboa com a distribuição de alguns edifícios antigos. Esta dissertação aborda o tema da Resistência residual de vigas de betão armado após incêndio para o qual o meio técnico e científico tem-se progressivamente consciencializado. Dois tipos de ensaios já conhecidos são realizados no LERF para avaliar o comportamento das vigas de betão armado após incêndio. O conhecimento das suas propriedades residuais é de grande importância para uma correta avaliação da capacidade resistente residual desses elementos. Foram realizados uma campanha experimental a fim de comparar a resistência de vigas em betão armado depois de submetidos ao incêndio ISO 834:1975. Para isso realizou-se o ensaio da metade de vigas ao fogo submetido a curva de incêndio ISO 834:1975 durante trinta minutos. Posteriormente realizou-se o ensaio de aplicação de carga a totalidade das vigas construídas considerando flexão simples, momentos positivos, simplesmente apoiadas e duas cargas pontuais descendentes aplicadas até ao seu rompimento Por fim, é realizado uma análise aos resultados obtidos fazendo a comparação entre os dois grupos de vigas (expostas e não expostas ao fogo) considerando o tipo de rotura, a capacidade resistente, as fissuras obtidas e as demais observações.pt
dc.description.abstractOver time there are numerous and irreparable human losses and property that have been happening due to fires. Reinforced concrete is the most common material used in construction today. At a certain unpredictability of a fire associated with its harmful influence on the strength of this material make it essential to study the behavior of reinforced concrete structural elements in fire, as well as the development of tools to check the resistance of the parts for the various seasons of resistance to fire regulations. The damage began these studies with more intensity from 1968, after the partial collapse of Ronan Point building on the outskirts of London caused by an exploding gas cylinder and its immediate collapse. Portugal only awakened to the impacts of fire on people's lives and assets years later, in 1988 after the Great Fire of the chiado´s stores in downtown Lisbon with the destruction of some ancient buildings. This dissertation addresses the issue of residual strength of concrete beams after fire for which the technical and scientific knowledge has gradually made aware. Two types of tests known in LERF are performed to evaluate the behavior of reinforced concrete beams after fire. The knowledge of their residual properties is of great importance for a correct assessment of residual resistant capacity of these elements. We performed an experimental campaign in order to compare the resistance of reinforced concrete beams subjected to fire after ISO 834:1975. For that half of the beams were tested subjected to fire curve ISO 834:1975 for thirty minutes. Subsequently held the test load application all of the bending beams constructed considering simple, positive moments, simply supported and two point loads applied to its descendants break Finally, we conducted an analysis of the results obtained by making a comparison between the two groups of beams (exposed and not exposed to fire) considering the type of failure, the load capacity, cracks and other observations obtained.pt
dc.language.isoporpt
dc.publisherUniversidade de Aveiropt
dc.rightsopenAccesspor
dc.subjectEngenharia civilpt
dc.subjectBetão armadopt
dc.subjectResistência ao fogopt
dc.subjectIncêndios - Edifíciospt
dc.titleResistência residual de vigas de betão armado após incêndiopt
dc.typemasterThesispt
thesis.degree.levelmestradopt
thesis.degree.grantorUniversidade de Aveiropt
Appears in Collections:UA - Dissertações de mestrado
DECivil - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
6195.PDF15.16 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.