Please use this identifier to cite or link to this item:
http://hdl.handle.net/10773/8741
Title: | Desempenho de dois métodos de detecção do anticoagulante lúpico |
Author: | Simões, Anabela Marques Carvalho |
Advisor: | Lourenço, Margarida Pereira, Maria de Lourdes |
Keywords: | Biologia molecular Anticoagulantes Sangue: Coagulação |
Defense Date: | 2011 |
Publisher: | Universidade de Aveiro |
Abstract: | O anticoagulante lúpico é um anticorpo adquirido, frequentemente associado a
tromboses venosas e/ou arteriais e complicações na gravidez, que interfere
com os testes de coagulação dependentes dos fosfolípidos. A sua detecção
laboratorial é baseada em critérios definidos pelo Subcomité de Anticoagulante
Lúpico/ Anticorpos Anti-Fosfolípidicos do Comité Científico de Normalização da
Sociedade Internacional de Trombose e Hemostase (2009). Os mesmos
recomendam a utilização de dois testes em simultâneo com distintos princípios
analíticos e diferentes concentrações de fosfolípidos. No presente trabalho
avaliou-se o comportamento de dois regentes comerciais (Lúpus Anticoagulant
da Siemens e Silica Clotting Time da Hemosil) na detecção laboratorial do
anticoagulante lúpico. Dado o reduzido número de amostras positivas
recomenda-se o prolongamento do estudo. Os reagentes mostraram um grau
de concordância excelente, no entanto, numa análise preliminar o reagente
Silica Clotting Time mostrou uma maior capacidade de detecção. De acordo
com esta observação foram propostos critérios de utilização dos dois
reagentes na rotina do Laboratório de Hematologia do Serviço de Patologia
Clínica dos Hospitais da Universidade de Coimbra, EPE. Lupus anticoagulants are acquired circulating anticoagulants that interfere with phospholipid -dependent coagulation tests and are frequently associated with thromboembolic disorders and obstetric complications. Lupus anticoagulants are diagnosed according to the criteria proposed by the Scientific and Standardization Committee on Lupus Anticoagulant/Antiphospholipid Antibodies of the International Society of Thrombosis and Hemostasis (2009). They recommend using two tests simultaneously with different analytical principles and different concentrations of phospholipids. In this study were evaluated the performance of two commercial regents (Lupus Anticoagulant of Siemens and Silica Clotting Time of Hemosil) in laboratory detection of LA. Given the low number of positive samples is recommended to extend the study. Reagents showed an excellent level of agreement, however, a preliminary analysis reagent Silica Clotting Time suggests have a greater capacity to detect. According to this observation were proposed criteria for use of two reagents in routine Hematology Laboratory of Clinical Pathology Service of the University Hospitals of Coimbra, EPE. |
Description: | Mestrado em Biologia Molecular e Celular |
URI: | http://hdl.handle.net/10773/8741 |
Appears in Collections: | UA - Dissertações de mestrado DBio - Dissertações de mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
250565.pdf | 732.59 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.