Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/6273
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCompleto, A.pt
dc.contributor.authorTalaia, P.pt
dc.contributor.authorFonseca, F.pt
dc.contributor.authorSimões, J. A.pt
dc.date.accessioned2012-02-13T14:59:23Z-
dc.date.issued2009-
dc.identifier.issn0261-3069pt
dc.identifier.urihttp://hdl.handle.net/10773/6273-
dc.description.abstractMaterials and design are important issues within general product development and even more in biomedical product. Knee prosthesis is a product that still lacks of adequate design solutions. Stress shielding and stress concentrations related to the end-of-stem pain are frequent clinical evidences that are intimately related to the design of the prosthesis and steins used in revision total knee arthroplasty, to the femoral and tibial components. Stress shielding and stress concentrations were assessed through finite element analyses of different tibial stem designs. Stress shielding was determined considering the relative minimal principal cancellous bone stresses between implanted and intact tibiae models. Scintigraphy and radiographs of painful implanted knees were assessed to correlate clinical findings with the finite element stresses. This study showed that stem design, geometry and material change the mechanical behavior of bone around tibial tray and stem in revision TKA. For the analyzed bone regions, underneath tibial tray and around the stem, the geometry of stem had a more pronounced bone effect comparatively to the stem material. The results of this study support that short stems produce a minor effect in bone relatively to long stein in terms of stress shielding and stress concentration at tip region. No significant stress shielding differences was observed between Co-Cr and titanium stems. Overall, all stems provoked high stress concentrations in bone at the tip of the stem. Scintigraphy of a painful implanted knee showed local osteoblastic activity and radiographs evidence bone ossification at the distal tip of the stem due the stress concentration. The results show that long stems induce very high distal stresses and are more prone to induce pain. A new concept of long stein with a distal polymeric (flexible material) tip reduces the magnitude of stresses at the end of the stem and therefore can theoretically contribute to reduce pain. (C) 2008 Elsevier Ltd. All rights reserved.pt
dc.language.isoengpt
dc.rightsrestrictedAccesspor
dc.subjectKnee arthroplastypt
dc.titleRelationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem painpt
dc.typearticlept
dc.peerreviewedyespt
ua.distributioninternationalpt
degois.publication.firstPage1391pt
degois.publication.issue4pt
degois.publication.issue4
degois.publication.lastPage1397pt
degois.publication.titleMaterials and Designpt
degois.publication.volume30pt
dc.date.embargo10000-01-01-
dc.identifier.doi10.1016/j.matdes.2008.06.071*
Appears in Collections:DEM - Artigos

Files in This Item:
File Description SizeFormat 
JMAD2022_versao_autor.pdfDocumento principal700.97 kBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.