Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/6120
Title: Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis
Author: Completo, A.
Rego, A.
Fonseca, F.
Ramos, A.
Relvas, C.
Simões, J.A.
Keywords: Revision total knee arthroplasty
Femur
Tibia
Press-fit stem
Cemented stem
Experimental strains
Issue Date: 2010
Abstract: Background: Recognized failure mechanisms after revision total knee arthroplasty include failure of fixation, instability and loosening. Thus, extended stems have been used to improve fixation and stability. In clinical cases where the stem is only applied in the femur, a question concerning the structural aspect of tibia may arise: Does a stemmed femur changes the structural behaviour of proximal tibia? It seems, that question has not yet been fully answered and the use of stems in the opposite bone structure requires further analysis. Methods: Proximal cortex strains were measured with tri-axial strain gauges in synthetic tibias for three different types of implanted femurs, with two constrained implants. To assess the strains at the cancellous bone under the tibial tray, it was considered a closest physiological load condition with the use of finite element models. Findings: No significant differences of the mean of the tibial cortex strains for the stemmed femur relatively to the stemless femur were observed. The R2 and slopes values of the linear regressions between experimental and finite element strains were close to one indicating good correlations. The strain behaviour of cancellous bone under the tibial tray is not completely immune to the use of femoral stem extensions. However, the level of this alteration is relatively small when compared with the strain magnitudes. Interpretation: The main insight given by the present study could probably lie in the fact that the use of femoral stems does not contribute to an increase of the risk of failure of the tibia.
Peer review: yes
URI: http://hdl.handle.net/10773/6120
DOI: 10.1016/j.clinbiomech.2009.10.011
ISSN: 0268-0033
Appears in Collections:DEM - Artigos

Files in This Item:
File Description SizeFormat 
2009_Biomechanical evaluation of proximal tibia behaviour with the use of femoral.pdfcópia final1.06 MBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.