Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/4293
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorNunes, Teresa Filomena Vieirapt
dc.contributor.advisorEvtyugina, Margarita Guennadievnapt
dc.contributor.authorSilva, Joana Raquel Rocha ept
dc.date.accessioned2011-11-08T12:53:29Z-
dc.date.available2011-11-08T12:53:29Z-
dc.date.issued2010-
dc.identifier.urihttp://hdl.handle.net/10773/4293-
dc.descriptionMestrado em Engenharia do ambientept
dc.description.abstractO material particulado suspenso no ar que respiramos, tem vindo a despertar cada vez mais interesse na comunidade científica, devido ao possível impacto negativo que pode causar na saúde humana. O objectivo deste estudo foi caracterizar química e biologicamente as partículas suspensas no ar (PM10) e para isso recolheram-se amostras, num período de sensivelmente duas semanas, em duas escolas básicas da cidade de Aveiro. Uma das escolas situa-se em ambiente tipicamente urbano (próxima do centro da cidade) e a outra situa-se na periferia, num ambiente com algumas características rurais. As amostras de material particulado foram recolhidas simultaneamente no interior e no exterior de cada estabelecimento de ensino, durante um período de 15 a 17 dias. Recolheram-se também amostras de dióxido de azoto (NO2) e de compostos orgânicos voláteis (COVs) de forma passiva, durante duas semanas, no interior e no exterior. Material biológico e parâmetros de conforto foram igualmente monitorizados. Para determinar a composição do material particulado analisou-se a concentração de carbonatos (CC), das fracções orgânica (CO) e elementar (CE) de carbono total (CT) e a fracção de compostos inorgânicos solúveis. As amostras de dióxido de azoto e de compostos orgânicos voláteis foram devidamente extraídas e analisadas. Para determinar a quantidade de material microbiológico, inocularam-se meios de cultura específicos para bactérias e fungos e fez-se a monitorização da evolução de cada amostra durante dez dias. Em ambas as escolas a concentração média de PM10, de CC, de CO e de COVs no interior foi significativamente superior à encontrada no exterior. As concentrações, em média, de NO2 e de compostos inorgânicos solúveis apresentaram valores médios menores no interior do que no exterior em ambos os estabelecimentos. No que diz respeito ao material microbiológico, verificou-se que relativamente às bactérias os valores obtidos no interior foram bastante mais elevados que os do exterior. Para os fungos, verificou-se uma quantidade ligeiramente superior no interior. Relativamente aos parâmetros de conforto, foram medidos Temperatura e Humidade Relativa, assim como concentrações de CO2 (de forma contínua), recorrendo a um analisador automático.pt
dc.description.abstractOver the past years, the particulate matter suspended in the air we breathe has become a topic of crescent interest to the scientific community due to its possible impact on human health. The aim of this study was to do a chemical and biological characterization of suspended particles (PM10), and to accomplish that, a number of samples were collected from two primary schools in Aveiro city. One of the schools is located on a typical urban environment, near to the centre of the city, and the other one is located in the suburbia with some rural characteristics. The samples were collected simultaneously indoors and outdoors of each building, during a 15 to 17 days period. Nitrogen dioxide (NO2) and volatile organic compounds (VOCs) were also collected by passive sampling indoors and outdoors. Biological material and comfort parameters were also monitored. To define the composition of the particulate matter the concentrations of carbonates (CC), organic (CO) and elemental (CE) fractions of total carbon (CT) and inorganic soluble material were analyzed. The samples of nitrogen dioxide and volatile organic compounds were properly extracted and analyzed. To determine the quantity of microbiological material, specific agar plates for bacterial and fungal were inoculated. The development of the colony-forming units was monitored during a ten day period. In both schools, the average concentrations of PM10, CC, CO and VOCs indoors were higher than the ones found outdoors. The average concentration of NO2 and inorganic soluble compounds were lower indoors than they were outdoors in both schools. In regards of the microbiological material, the values obtained for bacteria indoors were much higher than those obtained outdoors, whereas for fungi, although the values were higher indoors the difference wasn’t as significant. Comfort parameters like Temperature and Relative Humidity, were monitored as well as CO2 concentrations, with an automatic analyzer continuously.pt
dc.language.isoporpt
dc.publisherUniversidade de Aveiropt
dc.rightsopenAccesspor
dc.subjectEngenharia do ambientept
dc.subjectQualidade do ar: Escolas: Aveiropt
dc.subjectPartículas suspensaspt
dc.subjectMicroorganismospt
dc.subjectSaúde públicapt
dc.subjectExposição aos poluentespt
dc.titleCaracterização química e biológica de PM10 em ambiente escolarpt
dc.typemasterThesispt
thesis.degree.levelmestradopt
thesis.degree.grantorUniversidade de Aveiropt
Appears in Collections:DAO - Dissertações de mestrado
UA - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
dissertação.pdf3.23 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.