Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/37693
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFerreira, Nádia S.pt_PT
dc.contributor.authorCruz, Marco G. N.pt_PT
dc.contributor.authorGomes, Maria Teresa S.R.pt_PT
dc.contributor.authorRudnitskaya, Alisapt_PT
dc.date.accessioned2023-05-11T15:00:58Z-
dc.date.available2023-05-11T15:00:58Z-
dc.date.issued2018-05-01-
dc.identifier.issn0039-9140pt_PT
dc.identifier.urihttp://hdl.handle.net/10773/37693-
dc.description.abstractPotentiometric chemical sensors for the detection of paralytic shellfish toxins have been developed. Four toxins typically encountered in Portuguese waters, namely saxitoxin, decarbamoyl saxitoxin, gonyautoxin GTX5 and C1&C2, were selected for the study. A series of miniaturized sensors with solid inner contact and plasticized polyvinylchloride membranes containing ionophores, nine compositions in total, were prepared and their characteristics evaluated. Sensors displayed cross-sensitivity to four studied toxins, i.e. response to several toxins together with low selectivity. High selectivity towards paralytic shellfish toxins was observed in the presence of inorganic cations with selectivity coefficients ranging from 0.04 to 0.001 for Na+ and K+ and 3.6*10-4 to 3.4*10-5 for Ca2+. Detection limits were in the range from 0.25 to 0.9 μmolL-1 for saxitoxin and decarbamoyl saxitoxin, and from 0.08 to 1.8 μmolL-1 for GTX5 and C1&C2, which allows toxin detection at the concentration levels corresponding to the legal limits. Characteristics of the developed sensors allow their use in the electronic tongue multisensor system for simultaneous quantification of paralytic shellfish toxins.pt_PT
dc.language.isoengpt_PT
dc.publisherElsevierpt_PT
dc.relation31-03-05-FEP-0052pt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UID%2FAMB%2F50017%2F2013/PTpt_PT
dc.relationPOCI-01-0145-FEDER-007638pt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/FARH/SFRH%2FBPD%2F104265%2F2014/PTpt_PT
dc.rightsopenAccesspt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectChemical sensorspt_PT
dc.subjectParalytic shellfish toxinspt_PT
dc.subjectPotentiometrypt_PT
dc.subjectIonophorespt_PT
dc.titlePotentiometric chemical sensors for the detection of paralytic shellfish toxinspt_PT
dc.typearticlept_PT
dc.description.versionpublishedpt_PT
dc.peerreviewedyespt_PT
degois.publication.firstPage380pt_PT
degois.publication.lastPage384pt_PT
degois.publication.titleTalantapt_PT
degois.publication.volume181pt_PT
dc.identifier.doi10.1016/j.talanta.2018.01.031pt_PT
dc.identifier.essn1873-3573pt_PT
Appears in Collections:CESAM - Artigos
DQ - Artigos

Files in This Item:
File Description SizeFormat 
Potentiometric chemical sensors for the detection of paralytic shellfish toxins.pdf824.78 kBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.