Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/37591
Title: Ultra-low noise PEDOT:PSS electrodes on bacterial cellulose: a sensor to access bioelectrical signals in non-electrogenic cells
Author: Inácio, Pedro M.C.
Medeiros, Maria C.R.
Carvalho, Tiago
Félix, Rute C.
Mestre, Ana
Hubbard, Peter C.
Ferreira, Quirina
Morgado, Jorge
Charas, Ana
Freire, Carmen S.R.
Biscarini, Fabio
Power, Deborah M.
Gomes, Henrique L.
Keywords: PEDOT:PSS
Printed electronics
Bacterial cellulose
Extra-cellular electrodes
Non-excitable cells
Issue Date: Oct-2020
Publisher: Elsevier
Abstract: This study is focused on the particular advantages of organic-based devices to measure cells that do not generate action potentials, also known as non-electrogenic cells. While there is a vast literature about the application of organic conductors to measure neurons, cardiomyocytes and brain tissues, electrical measurements of non-electrogenic cells are rare. This is because non-electrogenic cells generate weak signals with frequencies below 1 Hz. Designing low noise devices in a millihertz frequency range is extremely challenging due to the intrinsic thermal and 1/f type noise generated by the sensing electrode. Here, we demonstrate that the coating of cellulose nanofibers with conducting PEDOT:PSS ink allows the fabrication of a nanostructured surface that establishes a low electrical double-layer resistance with liquid solutions. The low interfacial resistance combined with the large effective sensing area of PEDOT:PSS electrodes minimizes the thermal noise and lowers the amplitude detection limit of the sensor. The electrode noise decreases with frequency from 548 nV r.m.s at 0.1 Hz to a minimum of 6 nV r.m.s for frequencies higher than 100 Hz. This low noise makes it possible to measure low frequency bioelectrical communication signals, typical of non-electrogenic cells, that have until now been difficult to explore using metallic-based microelectrode arrays. The performance of the PEDOT:PSS-based electrodes is demonstrated by recording signals generated by populations of glioma cells with a signal-to-noise ratio as high as 140.
Peer review: yes
URI: http://hdl.handle.net/10773/37591
DOI: 10.1016/j.orgel.2020.105882
ISSN: 1566-1199
Appears in Collections:CICECO - Artigos
DQ - Artigos

Files in This Item:
File Description SizeFormat 
Ultra low noise PEDOTPSS electrodes on bacterial cellulose.pdf3.21 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.