Abstract: A presente dissertação, realizada no âmbito da unidade curricular Dissertação/Projeto/Estágio do Mestrado Integrado em Engenharia Mecânica da Universidade de Aveiro, tem como objetivo o estudo, do ponto de vista energético, de uma máquina de secar roupa com bomba de calor. Tal passou por identificar e caracterizar as necessidades energéticas inerentes ao processo de secagem de roupa. Após estas serem conhecidas, avaliou-se o potencial de utilização de uma bomba de calor por compressão de vapor para suprir estas necessidades energéticas. Foi realizada a simulação do processo de secagem de roupa, e a análise energética da máquina de secar roupa com bomba de calor, de modo a comparar este sistema com a máquina de secar roupa convencional. Por fim, estabeleceu-se o modelo físico da máquina de secar roupa incorporando uma bomba de calor por compressão de vapor, e foram apresentadas algumas sugestões de melhoria e propostas para trabalhos futuros.
The present Thesis, carried out within the scope of the Dissertation/Project/Internship course of the Integrated Master in Mechanical Engineering of the University of Aveiro, aims to study, from the energy point of view, a heat pump clothes dryer. This was made possible by identifying and characterizing the thermal energy needs inherent to the clothes drying process. Once these were evaluated, the potential of a vapor compression heat pump was evaluated in order to meet the thermal energy needs. It was performed the modeling and simulation of the clothes drying process, and the energy analysis of the of the drying process in both the heat pump and conventional clothes dryers. Lastly, it was established the physical model of the proposed tumble dryer incorporating a vapor compression heat pump. Conclusions and some improvement suggestions are presented, as well as some suggestions for future works.
URI: http://hdl.handle.net/10773/32196
Appears in Collections:UA - Dissertações de mestrado
DEM - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
Documento_Vasco_Cunha.pdf6.99 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.