Title: | Outdoor/indoor air quality in primary schools in Lisbon: a preliminary study |
Author: | Pegas, Priscilla Nascimento Evtyugina, Margarita G. Alves, Célia A. Nunes, Teresa Cerqueira, Mário Franchi, Mariana Pio, Casimiro Almeida, Susana Marta Freitas, Maria do Carmo |
Keywords: | Indoor air quality VOCs Formaldehyde |
Issue Date: | 2010 |
Publisher: | Sociedade Brasileira de Química |
Abstract: | Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO2 (2666 µg/m3), NO2 (40.3 µg/m3), VOCs (10.3 µg/m3), formaldehyde (1.03 µg/m3) and bioaerosols (1634 CFU/m3), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality. |
Peer review: | yes |
URI: | http://hdl.handle.net/10773/28675 |
DOI: | 10.1590/S0100-40422010000500027 |
ISSN: | 0100-4042 |
Appears in Collections: | CESAM - Artigos DAO - Artigos |