Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/27087
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAzevedo, Carlos Davide da Rochapt_PT
dc.contributor.advisorVeloso, Joãopt_PT
dc.contributor.authorSantana, Eduardo Franciscopt_PT
dc.date.accessioned2019-12-04T11:07:16Z-
dc.date.available2019-12-04T11:07:16Z-
dc.date.issued2019-01-30-
dc.identifier.urihttp://hdl.handle.net/10773/27087-
dc.description.abstractO conhecimento dos fenómenos associados à deriva de cargas em meios gasosos, especialmente eletrões, assume extrema importância para o estudo e compreensão de detetores gasosos de radiação. Ao longo deste trabalho foi estudado um novo tipo de detetor de radiação especialmente desenvolvida para deteção de eventos devidos ao efeito de Compton, que usa gás como meio de deteção, designada de Câmara Compton gasosa. Neste projeto, utilizou-se uma Câmara Compton gasosa em que foram caracterizados todos os seus componentes. Realizaram-se medidas para estudar a resposta em amplitude e resolução em função da variação do campo elétrico em diferentes regiões do fotossensor, onde se compararam as medições feitas com uma THCobra e um Readout simples com linhas ortogonais interligadas por uma ta resistiva. Mediu-se a amplitude e resolução em função do campo elétrico reduzido na região de deriva e cintilação da câmara de alta pressão do detetor. Além disso, adquiriram-se imagens 2D, embora usando apenas o efeito fotoelétricopt_PT
dc.description.abstractThe understanding of the physical behaviour of the drift of charged particles inside a gas, especially electrons, is vital for the study and undertstanding of gaseous radiation detectors. During this work a new type of radiation detector specially developed to detect Compton events was studied, so that it uses a gas as a detection medium, called gaseous Compton Camera. In this project, it was used a gaseous Compton Camera, which all its components were characterized. Measurements were performed to study the response of the amplitude and resolution as a function of the eletric field variation in different regions of the fotosensor, in which measurements with a THCobra and a simple Readout with ortogonal lines connected by a resistive strip. It was measured the amplitude and resolution as a function of the reduced electric field in the drift and scintillation region of the high pressure chamber of the detector. Furthermore, 2D images were acquired, although only via photoelectric effectpt_PT
dc.language.isoporpt_PT
dc.rightsopenAccesspt_PT
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectCâmara Comptonpt_PT
dc.subjectTHGEMpt_PT
dc.subjectFotocátodopt_PT
dc.subjectTHCobrapt_PT
dc.subjectRadiação γpt_PT
dc.subjectCsIpt_PT
dc.subjectEficiência quânticapt_PT
dc.subjectFotão UVVpt_PT
dc.titleDesenvolvimento de uma câmara Compton para medicina nuclearpt_PT
dc.typemasterThesispt_PT
thesis.degree.grantorUniversidade de Aveiropt_PT
dc.identifier.tid202237079-
dc.description.masterMestrado em Engenharia Físicapt_PT
Appears in Collections:UA - Dissertações de mestrado
DFis - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
Documento.pdf15.98 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.