Utilize este identificador para referenciar este registo: http://hdl.handle.net/10773/26989
Título: Optical fiber bioanalyzer based on enzymatic coating matrix for catecholamines and their metabolites assessment in patients with Down syndrome
Autor: Silva, Lurdes I. B.
Gomes, A. M.
Pintado, M. M.
Pinheiro, H.
Moura, D.
Freitas, Ana C.
Rocha-Santos, Teresa A. P.
Pereira, M. E.
Duarte, A. C.
Palavras-chave: Catecholamines analysis
Down syndrome
HPLC-ED
OF bioanalyzer
Data: 2012
Editora: Institute of Electrical and Electronics Engineers
Resumo: The urinary levels of catecholamines [adrenaline (AD), noradrenaline (NA), and dopamine (DA)] and their metabolites [L-3,4-dihydroxyphenylalanine (L-DOPA), and 3,4-dihydroxyphenylacetic acid (DOPAC)], as indicators of physiological stress, were assessed in 40 patients with Down syndrome (DS). The analysis was performed by an optical fiber (OF) bioanalyzer; which was constituted by two main components: a miniaturized chromatographic system and a detection system based on an OF coated with an enzymatic matrix. In this study some working conditions such as, number of fibers in the miniaturized chromatographic column, number of dips for sensitive coating deposition, temperature and time of cure of the sensitive matrix, were optimized in order to achieve higher analytical performance. After tested for calibration the bioanalyzer was applied to urine samples analysis of catecholamines and their metabolites, comparing the results with those obtained by both, a classical analytical method, namely high performance liquid chromatography coupled to an electrochemical detector (HPLC-ED), and an OF biosensor based on a sensitive cladding of laccase (LacOF biosensor). The results of catecholamines in patients with DS revealed that 15% and 22.5% of the analyzed subjects showed DA and AD concentrations, respectively, above the pathological levels. In the determinations of NA, the 40 samples showed concentration values below the normal levels, while in the determination of catecholamines metabolites 5% of the urine samples showed values above 118 and 1681 for L-DOPA and DOPAC, respectively.
Peer review: yes
URI: http://hdl.handle.net/10773/26989
DOI: 10.1109/JSEN.2011.2127471
ISSN: 1530-437X
Aparece nas coleções: CESAM - Artigos
DQ - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Silva et al. - 2012 - Optical Fiber Bioanalyzer Based on Enzymatic Coati.pdf920.92 kBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.