Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/25117
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSilva, Lurdes I. B.pt_PT
dc.contributor.authorFreitas, Ana C.pt_PT
dc.contributor.authorRocha-Santos, Teresa A. P.pt_PT
dc.contributor.authorPereira, M. E.pt_PT
dc.contributor.authorDuarte, Armando C.pt_PT
dc.date.accessioned2019-01-15T15:26:01Z-
dc.date.available2019-01-15T15:26:01Z-
dc.date.issued2011-
dc.identifier.issn0039-9140pt_PT
dc.identifier.urihttp://hdl.handle.net/10773/25117-
dc.description.abstractBreath analysis constitutes a promising tool in clinical and analytical fields due to its high potential for non-invasive diagnostics of metabolic disorders and monitoring of disease status. An optical fiber (OF) sensor has been developed for determination of volatile organic compounds (ethane, pentane, heptane, octane, decane, benzene, toluene and styrene) in human breath for clinical diagnosis. The analytical system developed showed a high performance for breath analysis, inferred for the analytical signal intensity and stability, linear range, and detection limits ranging from 0.8 pmol L−1, for heptane, and to 9.5 pmol L−1, for decane. The OF sensor also showed advantageous features of near real-time response and low instrumentation costs, besides showing an analytical performance equivalent to the breath analysis by gas chromatography–mass spectrometry (GC–MS), used as the reference method.pt_PT
dc.language.isoengpt_PT
dc.publisherElsevierpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/70970/PTpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/99042/PTpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBPD%2F48028%2F2008/PTpt_PT
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBPD%2F65410%2F2009/PTpt_PT
dc.rightsrestrictedAccesspt_PT
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectBreath analysispt_PT
dc.subjectOptical fiber sensorspt_PT
dc.subjectVolatile organic compoundspt_PT
dc.titleBreath analysis by optical fiber sensor for the determination of exhaled organic compounds with a view to diagnosticspt_PT
dc.typearticlept_PT
dc.description.versionpublishedpt_PT
dc.peerreviewedyespt_PT
degois.publication.firstPage1586pt_PT
degois.publication.issue5pt_PT
degois.publication.lastPage1594pt_PT
degois.publication.titleTalantapt_PT
degois.publication.volume83pt_PT
dc.identifier.doi10.1016/j.talanta.2010.11.056pt_PT
dc.identifier.essn1873-3573pt_PT
Appears in Collections:CESAM - Artigos
DQ - Artigos

Files in This Item:
File Description SizeFormat 
Silva et al. - 2011 - Breath analysis by optical fiber sensor for the de.pdf984.27 kBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.