Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/2445
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMartins, Nelson Amadeu Diaspor
dc.contributor.authorDinis, João Diogo Matiaspor
dc.coverage.spatialAveiropor
dc.date.accessioned2011-04-19T13:59:54Z-
dc.date.available2011-04-19T13:59:54Z-
dc.date.issued2008por
dc.identifier.urihttp://hdl.handle.net/10773/2445-
dc.descriptionMestrado em Engenharia Mecânicapor
dc.description.abstractO isolamento térmico é uma das medidas mais eficientes para a conservação da energia de arrefecimento e aquecimento nos edifícios. Portanto, determinar e seleccionar a espessura óptima de isolamento térmico é um assunto de extrema importância. O isolamento tem sido alvo de um interesse crescente nos últimos anos, não só pelo facto ambiental de consumo energético, mas também pelo preço crescente e elevado da energia. Em países que importam a maioria da energia, como é o caso de Portugal, a poupança de energia e o seu uso eficiente, têm-se tornado aspectos relevantes. O consumo de energia dispendida para aquecimento nas diversas regiões é elevado porque existe falta de isolamento térmico nos edifícios. Portanto, a espessura óptima de isolamento térmico, foi calculada para formas de energia e tempos de ciclo de vida diferentes para as três regiões climáticas de aquecimento de Portugal. Neste estudo a determinação da espessura de isolamento térmica é baseada na análise económica de ciclo de vida. O método mais simples e intuitivo de estimar o consumo energético usado foi o método graus – dias. O RCCTE (DL 80/2006) é um novo regulamento das características de comportamento térmico de edifícios em Portugal. Não se sabia, se a espessura exigida neste regulamento, se tratava da espessura económica que tomava em conta as diferentes zonas climáticas e o custo da energia. A espessura óptima de isolamento térmico para as paredes exteriores para 20 anos de tempo de ciclo de vida varia entre 0,058 e 0,122 m para a região I1, 0,075 e 0,150 m para a região I2 e 0,097 e 0,188 m para a região I3, dependendo da forma de energia. Para 40 anos de tempo de ciclo de vida, a espessura óptima para as paredes externas varia de 0,084 a 0,166 m para a região I1, 0,106 a 0,204 m para a região I2 e 0,135 a 0,251 m para a região I3, dependendo da forma de energia. Valores algo diferentes dos recomendados pelo RCCTE. O valor do tempo de retorno do investimento encontra-se abaixo de 4,6 anos para 20 anos de tempo de ciclo de vida e 5,6 anos para 40 anos de tempo de ciclo de vida. Por outro lado, existem softwares de distribuição gratuita para verificar o regulamento presente. Foi mostrado que estes softwares não são fiáveis tendo em conta a discrepância de valores apresentados quando sujeitas ao cálculo de situações idênticas. Nestes softwares, o cálculo da área equivalente de envidraçado não é bem realizado relativamente à folha de cálculo. ABSTRACT: Thermal insulation is one of the most effective energy conservation measures for cooling and heating in buildings. Therefore determining and selecting the optimum thickness of insulation is a important issue to take into account. Insulation of buildings has been gaining much more interest in recent years not only for the environmental effect of the consumed energy but also the high cost of energy. In countries that import most of their energy, like Portugal, energy saving and the effective usage of energy become much more important. Energy consumption for heating in different zones is too high in Portugal because buildings have a lack of insulation. Therefore, the optimum insulation thickness for different energy sources and two different life cycle times are calculated for the three different climate zones in Portugal. In this study the determination of optimum insulation thickness is based on the life cycle cost analyses. The degree-days method that is the simplest and most intuitive way of estimating the annual energy consumption of a building is also used in this study. The RCCTE - (DL 80/2006) is a new regulation of the characteristics of thermal behaviour of buildings in Portugal. This regulation demands minimum thermal qualities in building envelope. Isn’t known if the insulation thickness required in this regulation is the economic insulation thickness who takes into account local climate zone and the cost of energy. The optimum insulation thickness for external walls for 20 years of life cycle varies between 0,058 to 0,122 m in the climate zone I1, 0,075 to 0,150 m in the climate zone I2 and 0,097 to 0,188 m in the climate zone I3 depending of the energy used. For 40 years of life cycle the optimum insulation thickness for external wall varies between 0,084 to 0,166 m for climate zone I1, 0,106 to 0,204 m and for climate zone I2 and 0,135 to 0,251 m for climate zone I3. The payback period is lower than 4,6 years for 20 years of life cycle e 5,6 years for 40 years of life cycle. In other hand there are free software’s to verify the present regulation. It was shown that these software’s were not reliable whereas compared in the same situation. In these software’s the calculation of the equivalent glazing area isn’t well done compared to spreadsheet.por
dc.language.isoporpor
dc.publisherUniversidade de Aveiropor
dc.relation.urihttp://opac.ua.pt/F?func=find-b&find_code=SYS&request=000209833por
dc.rightsopenAccesspor
dc.subjectCasas de habitaçãopor
dc.subjectIsolamento térmicopor
dc.subjectComportamento térmicopor
dc.subjectPoupança de energiapor
dc.titleAnálise do nível óptimo de isolamento térmico de edifícios residenciais em Portugalpor
dc.typemasterThesispor
thesis.degree.levelMestradopor
thesis.degree.grantorUniversidade de Aveiropor
Appears in Collections:UA - Dissertações de mestrado
DEM - Dissertações de mestrado