Please use this identifier to cite or link to this item:
http://hdl.handle.net/10773/2394
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Cachim, Paulo | por |
dc.contributor.author | Silva, Ruben Filipe Pereira da | por |
dc.coverage.spatial | Aveiro | por |
dc.date.accessioned | 2011-04-19T13:58:17Z | - |
dc.date.available | 2011-04-19T13:58:17Z | - |
dc.date.issued | 2009 | por |
dc.identifier.uri | http://hdl.handle.net/10773/2394 | - |
dc.description | Mestrado em Engenharia Civil | por |
dc.description.abstract | Nas estruturas de madeira as ligações são pontos críticos, constituem locais de transmissão de esforços, que condicionam o desempenho global da estrutura. É necessário garantir ligações compatíveis com as solicitações impostas, em condições normais e em situação de incêndio. Este trabalho consiste no cálculo segundo o Eurocódigo 5 – Cálculo de estruturas de madeira, de diferentes ligações, com ligadores tipo cavilha e conectores, para temperatura ambiente e em situação de incêndio. São analisados, a escolha dos ligadores em função da carga/geometria da ligação e os resultados obtidos para um tempo de resistência ao fogo de 30 e 60 minutos, considerando ligações protegidas e desprotegidas. O Eurocódigo 5, parte 1-2 – Dimensionamento ao fogo, apresenta dois métodos de cálculo, o método simplificado, de natureza empírica e o método de redução da carga, de base experimental. No presente trabalho realizou-se uma análise comparativa dos resultados obtidos aplicando separadamente cada método. Utilizaram-se também ligações protegidas, tendo-se verificado que este é um modo eficaz e fácil de conseguir uma elevada resistência ao fogo das ligações. ABSTRACT: In timber structures, joints are critical points, places where the forces are transmitted between the members, which determine the overall performance of the structure. It is necessary to ensure that joints are compatible with the loads in normal and fire situations. This work consists in the design, according the Eurocode 5 – Structural timber design, of different connections with dowel-type fasteners and connectors, at room temperature and fire loading. The choice of fasteners was carried out according to the load/geometry of the joint, and the results obtained for 30 and 60 minutes of fire resistance, for protected and unprotected connections. The Eurocode 5 part 1-2 – Structural fire design, gives two different calculation methods: the simplified method, mostly empirical, and the reduced load method, based on experimental results. In this work a comparative analysis of the results obtained with each method is presented. In addition protected connections were also used and the results showed that this is an effective and easy way to achieve a high fire resistance. | por |
dc.language.iso | por | por |
dc.publisher | Universidade de Aveiro | por |
dc.relation.uri | http://opac.ua.pt/F?func=find-b&find_code=SYS&request=000231501 | por |
dc.rights | openAccess | por |
dc.subject | Engenharia civil | por |
dc.subject | Construções em madeira | por |
dc.subject | Estruturas (construção) | por |
dc.subject | Resistência ao fogo | por |
dc.title | Cálculo ao fogo de ligações de madeira | por |
dc.type | masterThesis | por |
thesis.degree.level | Mestrado | por |
thesis.degree.grantor | Universidade de Aveiro | por |
Appears in Collections: | UA - Dissertações de mestrado DECivil - Dissertações de mestrado |
Files in This Item:
File | Size | Format | |
---|---|---|---|
2010000232.pdf | 1 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.