dc.descriptionMestrado em Engenharia Civilpor
dc.description.abstractNas estruturas de madeira as ligações são pontos críticos, constituem locais de transmissão de esforços, que condicionam o desempenho global da estrutura. É necessário garantir ligações compatíveis com as solicitações impostas, em condições normais e em situação de incêndio. Este trabalho consiste no cálculo segundo o Eurocódigo 5 – Cálculo de estruturas de madeira, de diferentes ligações, com ligadores tipo cavilha e conectores, para temperatura ambiente e em situação de incêndio. São analisados, a escolha dos ligadores em função da carga/geometria da ligação e os resultados obtidos para um tempo de resistência ao fogo de 30 e 60 minutos, considerando ligações protegidas e desprotegidas. O Eurocódigo 5, parte 1-2 – Dimensionamento ao fogo, apresenta dois métodos de cálculo, o método simplificado, de natureza empírica e o método de redução da carga, de base experimental. No presente trabalho realizou-se uma análise comparativa dos resultados obtidos aplicando separadamente cada método. Utilizaram-se também ligações protegidas, tendo-se verificado que este é um modo eficaz e fácil de conseguir uma elevada resistência ao fogo das ligações. ABSTRACT: In timber structures, joints are critical points, places where the forces are transmitted between the members, which determine the overall performance of the structure. It is necessary to ensure that joints are compatible with the loads in normal and fire situations. This work consists in the design, according the Eurocode 5 – Structural timber design, of different connections with dowel-type fasteners and connectors, at room temperature and fire loading. The choice of fasteners was carried out according to the load/geometry of the joint, and the results obtained for 30 and 60 minutes of fire resistance, for protected and unprotected connections. The Eurocode 5 part 1-2 – Structural fire design, gives two different calculation methods: the simplified method, mostly empirical, and the reduced load method, based on experimental results. In this work a comparative analysis of the results obtained with each method is presented. In addition protected connections were also used and the results showed that this is an effective and easy way to achieve a high fire resistance.por
dc.language.isoporpor
dc.publisherUniversidade de Aveiropor
dc.relation.urihttp://opac.ua.pt/F?func=find-b&find_code=SYS&request=000231501por
dc.rightsopenAccesspor
dc.subjectEngenharia civilpor
dc.subjectConstruções em madeirapor
dc.subjectEstruturas (construção)por
dc.subjectResistência ao fogopor
dc.titleCálculo ao fogo de ligações de madeirapor
dc.typemasterThesispor
thesis.degree.levelMestradopor
thesis.degree.grantorUniversidade de Aveiropor
Appears in Collections:UA - Dissertações de mestrado
DECivil - Dissertações de mestrado

Files in This Item:
File SizeFormat 
2010000232.pdf1 MBAdobe PDFView/Open


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.