Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/23497
Title: Sistema de purificação selado para detetor de imagiologia de raios X
Author: Sousa, Sara Cristina Neves de
Advisor: Veloso, João
Carramate, Lara Filipa das Neves Dias
Keywords: Engenharia física
Detectores de gases
Difracção de raios X
Purificação de gases
Defense Date: 2017
Publisher: Universidade de Aveiro
Abstract: Este trabalho consistiu no estudo da performance de um detetor gasoso microestruturado (MPGD) desenvolvido para fins de imagiologia de raios X, nomeadamente para imagiologia de contagem de fotão único. O detetor utilizado baseia-se numa microestrutura Thick-COBRA 2D (2D-THCOBRA), com área ativa de 2; 8 2; 8 cm2. Esta microestrutura permite dois estágios independentes de multiplicação de carga, que resultam num ganho elevado e adequado a aplicações de imagiologia. O detetor utilizado opera em modo selado numa atmosfera de Kr puro a 1 bar. Desenvolveu-se um sistema fechado de purificação de gás baseado em getters com o objetivo de reciclar o gás, evitando os custos associados a um sistema de fluxo contínuo de gases dispendiosos e com o intuito de manter a performance do detetor constante. O propósito deste trabalho era estudar a influência do sistema de purificação de gás no desempenho do detetor. Para tal, este foi testado em termos de ganho em carga, resolução em energia e estabilidade temporal do ganho. Também se adquiriram imagens de transmissão de raios X de algumas amostras com o objetivo de expor as potencialidades deste detetor para imagiologia de raios X. Efetuou-se uma monitorização contínua do ganho ao longo de 41 dias e pôde-se observar que o detetor apresentava uma operação estável, com variações de ganho de apenas 6; 5%. Esta monitorização permitiu também observar a eficiência do sistema de purificação baseado em getters. Obteve-se um ganho máximo de 2; 5 103 para 5; 9 keV e uma resolução em energia de 11;6% para 22 keV em Kr.
This work consisted of the study of the performance of a MicroPattern Gaseous Detector (MPGD) developed for x-ray imaging, namely for single photon counting imaging. The detector was based on a 2D Thick-COBRA microstructure (2D-THCOBRA), with an active area of 2; 8 2; 8 cm2. This microstructure allows for two independent charge multiplication stages that result in high gains that are suitable for imaging applications. The detector operates in sealed mode, in an atmosphere of pure Kr at 1 bar. A closed gas puri cation system based on getters was developed with the purpose of recycling the gas, avoiding the costs associated with a continuous ow of expensive gases and with the aim of keeping a stable detector performance. The purpose of this work was to study the in uence of the gas puri cation system on the performance of the detector. Thus the detector was evaluated in terms of charge gain, energy resolution and gain stability over time. Some X-ray transmition images were also aquired with the aim of showing the detector's capabilities for X-ray imaging. A continuous monitorization was held over a period of 41 days and a stable detector operation was observed, with gain uctuations of just 6:5%. Through this monitorization the e ciency of the puri cation system based on getters was also observed. A charge gain of 2; 5 103 was obtained for 5; 9 keV and an energy resolution of 11; 6% was obtained for 22 keV in Kr.
Description: Mestrado em Engenharia Física
URI: http://hdl.handle.net/10773/23497
Appears in Collections:FIS - Dissertações de mestrado
UA - Dissertações de mestrado

Files in This Item:
File Description SizeFormat 
DissertaçãoSaraSousa.pdf8.27 MBAdobe PDFView/Open


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.