Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/19638
Title: Preliminary research on the use of SVET in non-aqueous media
Author: Bastos, A. C.
Quevedo, M. C.
Ferreira, M. G. S.
Keywords: SCANNING VIBRATING ELECTRODE
PITTING CORROSION
ALUMINUM-ALLOY
GALVANIC CORROSION
ELECTRICAL-FIELDS
STAINLESS-STEEL
CARBON-STEEL
PROBE
ZINC
INHIBITION
Issue Date: 2016
Publisher: PERGAMON-ELSEVIER SCIENCE LTD
Abstract: An investigation is presented on the use of the scanning vibrating electrode technique (SVET) in nonaqueous media, namely pure ethanol and ethanol saturated with NaCl. The SVET was able to measure the ionic currents flowing in the liquid phase between anodes and cathodes in electrochemical systems such as platinum disk electrodes connected to a battery, a zinc-iron galvanic couple, painted galvanised steel with artificial defects and alumina coated cast aluminium alloy. The results show the applicability of the technique in non-aqueous highly resistive medium. (C) 2015 Elsevier Ltd. All rights reserved.
Peer review: yes
URI: http://hdl.handle.net/10773/19638
DOI: 10.1016/j.electacta.2015.12.107
ISSN: 0013-4686
Publisher Version: 10.1016/j.electacta.2015.12.107
Appears in Collections:CICECO - Artigos

Files in This Item:
File Description SizeFormat 
Preliminary research on the use of SVET in non-aqueous media_10.1016j.electacta.2015.12.107.pdf2.67 MBAdobe PDFrestrictedAccess


FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 