Please use this identifier to cite or link to this item: http://hdl.handle.net/10773/19210
Title: Good's buffers as a basis for developing self-buffering and biocompatible ionic liquids for biological research
Author: Taha, Mohamed
Silva, Francisca A. e
Quental, Maria V.
Ventura, Sonia P. M.
Freire, Mara G.
Coutinho, Joao A. P.
Keywords: AQUEOUS BIPHASIC SYSTEMS
BOVINE SERUM-ALBUMIN
2-PHASE SYSTEMS
TOXICITY
AGGREGATION
STABILITY
MEDIA
SALTS
WATER
SPECTROSCOPY
Issue Date: 2014
Publisher: ROYAL SOC CHEMISTRY
Abstract: This work reports a promising approach to the development of novel self-buffering and biocompatible ionic liquids for biological research in which the anions are derived from biological buffers (Good's buffers, GB). Five Good's buffers (Tricine, TES, CHES, HEPES, and MES) were neutralized with four suitable hydroxide bases (1-ethyl-3-methylimidazolium, tetramethylammonium, tetraethylammonium, and tetrabutylammonium) producing 20 Good's buffer ionic liquids (GB-ILs). The presence of the buffering action of the synthesized GB-ILs was ascertained by measuring their pH-profiles in water. Moreover, a series of mixed GB-ILs with wide buffering ranges were formulated as universal buffers. The impact of GB-ILs on bovine serum albumin (BSA), here used as a model protein, is discussed and compared with more conventional ILs using spectroscopic techniques, such as infrared and dynamic light scattering. They appear to display, in general, a greater stabilizing effect on the protein secondary structure than conventional ILs. A molecular docking study was also carried out to investigate on the binding sites of GB-IL ions to BSA. We further used the QSAR-human serum albumin binding model, log K(HSA), to calculate the binding affinity of some conventional ILs/GB-ILs to HSA. The toxicity of the GB and GB-ILs was additionally evaluated revealing that they are non-toxic against Vitro fischeri. Finally, the GB-ILs were also shown to be able to form aqueous biphasic systems when combined with aqueous solutions of inorganic or organic salts, and we tested their extraction capability for BSA. These systems were able to extract BSA with an outstanding extraction efficiency of 100% in a single step for the GB-IL-rich phase, and, as a result, the use of GB-IL-based ABS for the separation and extraction of other added-value biomolecules is highly encouraging and worthy of further investigation.
Peer review: yes
URI: http://hdl.handle.net/10773/19210
DOI: 10.1039/c4gc00328d
ISSN: 1463-9262
Publisher Version: 10.1039/c4gc00328d
Appears in Collections:CICECO - Artigos



FacebookTwitterLinkedIn
Formato BibTex MendeleyEndnote Degois 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.