 Axially loaded stainless steel columns in case of fire
Please use this identifier to cite or link to this item http://hdl.handle.net/10773/5555

title: Axially loaded stainless steel columns in case of fire
authors: Lopes, Nuno
Real, Paulo Vila
Silva, Luís Simões da
Franssen, Jean Marc
issue date: 2010
publisher: Multi-Science Publishing Co. Ltd
abstract: The simple model of Eurocode 3, for the fire resistance evaluation of stainless steel members, are based on the procedures used for carbon steel structural elements. However, due to the existing differences in the constitutive laws of these two materials, it is expected that it would not be possible to use, in both materials, the same formulae for the member stability calculation, as proposed in Eurocode 3. This paper aims at increasing the knowledge on the behaviour of stainless steel axially loaded columns at elevated temperatures. For this purpose, a geometrical and material non linear computer code has been used to determine the buckling load of these elements. The Eurocode formulae are evaluated and a new proposal, that ensures accurate and conservative results when compared with the numerical simulations, is presented.
URI: http://hdl.handle.net/10773/5555
ISSN: 2040-2317
publisher version/DOI: http://www.multi-science.co.uk/
source: Journal of Structural Fire Engineering
appears in collectionsCIVIL - Artigos

files in this item

file description sizeformat
RI9-JSFE-10.pdf1.07 MBAdobe PDFview/open
Restrict Access. You can Request a copy!
statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! RCAAP OpenAIRE DeGóis
ria-repositorio@ua.pt - Copyright ©   Universidade de Aveiro - RIA Statistics - Powered by MIT's DSpace software, Version 1.6.2