DSpace
 
  Repositório Institucional da Universidade de Aveiro > Departamento de Engenharia Mecânica > MEC - Dissertações de mestrado >
 Impedance control of a hydraulic servomechanism
Please use this identifier to cite or link to this item http://hdl.handle.net/10773/2491

title: Impedance control of a hydraulic servomechanism
authors: Cwiklinski, Marcin Stefan
advisors: Ferreira, Jorge Augusto Fernandes
keywords: Engenharia mecânica
Sistemas hidráulicos
Manipuladores robóticos
Controlo hidráulico
issue date: 2009
publisher: Universidade de Aveiro
abstract: No presente trabalho é proposto e implementado um controlador de impedância baseado na posição para o controlo de um cilindro, instalado numa prensa hidráulica, comandado por uma servoválvula actuada por solenóide. Foram inicialmente desenvolvidos controladores de posição, controlador PID e controlador baseado em lógica difusa, com os requisitos de precisão adequados à implementação do controlador de impedância baseado na posição. O filtro de impedância foi colocado na malha de realimentação de força para modificar a trajectória do actuador hidráulico de acordo com o comportamento especificado. Simultaneamente com as experiências na prensa hidráulica, o controlo de impedância foi experimentado em ambiente totalmente simulado recorrendo a um modelo não linear de todo o sistema hidráulico (cilindro + servoválvula). Foram realizadas várias experiências em espaço livre e em contacto com o ambiente. Foram conseguidos resultados satisfatórios em ambas as situações bem como na transição de não-contacto para contacto com o ambiente. ABSTRACT: A position-based impedance controller is proposed and demonstrated on an existing hydraulic press with a two-way vertically mounted hydraulic cylinder driven by a servo-solenoid valve. A proportional-integral-derivative (PID) controller and a Fuzzy Logic Controller (FLC) are primarily developed to meet the accurate positioning requirements of the impedance control formulation. The impedance filter was placed in force-feedback loop to modify a desired trajectory of the hydraulic actuator according to a specified behavior. Simultaneously with the experiment conducted on the real hydraulic press, impedance control was performed in computer simulation with the use of a nonlinear model of the whole hydraulic system (cylinder + servo solenoid valve). Experiments were carried out in free space and with environmental contact. Satisfactory results were achieved in both situations, as well as in noncontact/ contact transition.
description: Mestrado em Engenharia Mecânica
URI: http://hdl.handle.net/10773/2491
appears in collectionsMEC - Dissertações de mestrado
UA - Dissertações de mestrado

files in this item

file sizeformat
2009001091.pdf2.24 MBAdobe PDFview/open
statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! RCAAP OpenAIRE DeGóis
ria-repositorio@ua.pt - Copyright ©   Universidade de Aveiro - RIA Statistics - Powered by MIT's DSpace software, Version 1.6.2